Reading and acknowledging error states
Description
The function block KRC_Error collectively reads and acknowledges the current error state of the mxA interface, the error state of the robot controller and the error state of the function blocks.
If more than one error has occurred in the function block at the same time, only the error number of the most recent error is displayed. Errors in a function block cause the motion enable to be canceled.
If more than one error has occurred at the same time, these errors are displayed with the following priority ranking:
- Errors of the mxA interface in the robot interpreter
- Errors of the mxA interface in the submit interpreter
- ProConOS errors
- Errors in the PLC
- Errors in a function block of the local PLC
- Errors in the robot controller
The function block KRC_Error contains all diagnostic function blocks, which means that this block displays all important diagnostic data.
Inputs
|
Parameter |
Type |
Description |
|---|---|---|
|
AxisGroupIdx |
INT |
Index of axis group
|
|
MessageReset |
BOOL |
Acknowledges error messages of the mxA interface and the robot controller TRUE = reset message Note: The messages can only be reset if the robot is stationary. |
Outputs
|
Parameter |
Type |
Description |
|---|---|---|
|
Error |
BOOL |
TRUE = error in function block |
|
ErrorID |
INT |
Error number |
|
NoHeartbeatKRC |
BOOL |
The submit interpreter is not sending a life sign |
|
NoHeartbeatPCOS |
BOOL |
ProConOS is not sending a life sign |
|
NotOnline |
BOOL |
No connection to robot controller |
|
NotInitialized |
BOOL |
No statements can be executed, as the connection has not been initialized. |
|
NoOpModeExt |
BOOL |
Robot is not in Automatic External mode |
|
NoMoveEnable |
BOOL |
No motion enable present. |
|
UserSafeNotOK |
BOOL |
The operator safety is violated. The $USER_SAF signal of the Automatic External interface is not active. |
|
KrcErrorActive |
BOOL |
Error messages of the robot controller are active. The $STOPMESS signal of the Automatic External interface is active. |
|
DrivesNotReady |
BOOL |
The drives are not ready. The $PERI_RDY signal of the Automatic External interface is not active. |
|
NoProgActive |
BOOL |
The robot program is not active. The $PRO_ACT signal of the Automatic External interface is not active. |