Approaching an absolute Cartesian position as quickly as possible
Description
The function block KRC_MoveDirectAbsolute executes a point-to-point motion to a Cartesian end position. The coordinates of the end position are absolute.
The robot moves as quickly as possible to the end position. The fastest path is generally not the shortest path and is thus not a straight line. This corresponds to a PTP motion on the robot system.
![]() | If the motion is executed as a spline motion, the following must be taken into consideration: If the motion is approximated and there is no further motion instruction in the buffer, the output “Done” is not set for the spline motion. In this case, the motion is not ended at the end point, but at the approximate positioning point. |
Inputs
|
Parameter |
Type |
Description |
|---|---|---|
|
AxisGroupIdx |
INT |
Index of axis group
|
|
ExecuteCmd |
BOOL |
Starts/buffers the motion in the case of a rising edge of the signal. |
|
Position |
E6POS |
Coordinates of the Cartesian end position (>>> E6POS) The data structure E6POS contains all components of the end position (= position of the TCP relative to the origin of the BASE coordinate system). Note: If the value -1 is transferred for Status and Turn, the shortest path to the end position is taken. |
|
Velocity |
INT |
Velocity
Refers to the maximum value specified in the machine data. The maximum value is dependent on the robot type and refers to the value of DEF_VEL_CP of the robot system. Default: 0% (= velocity is not changed) |
|
Acceleration |
INT |
Acceleration
Refers to the maximum value specified in the machine data. The maximum value is dependent on the robot type and refers to the value of DEF_ACC_CP of the robot system. Default: 0% (= acceleration is not changed) |
|
CoordinateSystem |
COORDSYS |
Coordinate system to which the Cartesian coordinates of the end position refer (>>> COORDSYS) |
|
Approximate |
APO |
Approximation parameter (>>> APO) |
|
BufferMode |
INT |
Mode in which the statement is executed
(>>> BufferMode) |
|
SplineMode |
BOOL |
TRUE = motion is executed as a spline motion. FALSE = motion is executed as a conventional point-to-point motion. |
Outputs
|
Parameter |
Type |
Description |
|---|---|---|
|
Busy |
BOOL |
TRUE = statement is currently being transferred or has already been transferred |
|
Active |
BOOL |
TRUE = motion is currently being executed |
|
Done |
BOOL |
TRUE = motion has stopped |
|
Aborted |
BOOL |
TRUE = statement/motion has been aborted |
|
Error |
BOOL |
TRUE = error in function block |
|
ErrorID |
DINT |
Error number |