ItpStartStop
![]()  | Outdated version The sole purpose of the function block is to ensure compatibility with existing projects. For new projects please use the function block ItpStartStopEx.  | 
 Inputs
VAR_INPUT
    bStart         : BOOL;
    bStop          : BOOL;
    nChnId         : UDINT;
    tTimeOut       : TIME;
END_VARName  | Type  | Description  | 
|---|---|---|
bStart  | BOOL  | A positive edge starts the NC channel.  | 
bStop  | BOOL  | A positive edge stops the NC channel. A stop command deletes all the tables in the NC and brings the axes to a controlled halt.  | 
nChnId  | UDINT  | Channel ID  | 
tTimeOut  | TIME  | ADS Timeout-Delay  | 
![]()  | The bStop input has a higher priority than the bStart input, so that if both inputs receive a positive edge, a channel stop will be executed.  | 
 Outputs 
VAR_OUTPUT
    bBusy     : BOOL;
    bErr      : BOOL;
    nErrId    : UDINT;
END_VAR Name  | Type  | Description  | 
|---|---|---|
bBusy  | BOOL  | This output remains TRUE until the function block has executed a command, but at the longest for the duration supplied to the 'Timeout' input. While Busy = TRUE, no new command will be accepted at the inputs. Please note that it is not the execution of the service but its acceptance whose time is monitored.  | 
bErr  | BOOL  | This output is switched to TRUE as soon as an error occurs during the execution of a command. The command-specific error code is contained in 'nErrId'. Is reset to FALSE by the execution of a command at the inputs.  | 
nErrId  | UDINT  | Contains the command-specific error code of the most recently executed command. Is reset to 0 by the execution of a command at the inputs. The error numbers in ErrId can be looked up in the ADS error documentation or in the NC error documentation (error codes above 0x4000).  | 
Requirements
| 
                   Development environment  | 
                   Target platform  | 
                   PLC libraries to be linked  | 
|---|---|---|
| 
                   TwinCAT v3.1.0  | 
                   PC or CX (x86 or x64)  | 
                   Tc2_NCI  | 