ItpSetZeroShiftNull
The function block ItpSetZeroShiftNull overwrites all zero offset shifts of the channel with zero.
|  | Outdated version The sole purpose of the function block is to ensure compatibility with existing projects. For new projects please use the function block ItpSetZeroShiftNullEx. | 
 Inputs
 Inputs
VAR_INPUT
    bExecute       : BOOL;
    nChnId         : UDINT;
    tTimeOut       : TIME;
END_VAR| Name | Type | Description | 
|---|---|---|
| bExecute | BOOL | A rising edge results in overwriting of all zero offset shifts of the NC channel with zero. | 
| nChnId | UDINT | ID of the NC channel | 
| tTimeOut | TIME | ADS Timeout-Delay | 
 Outputs
 Outputs 
VAR_OUTPUT
    bBusy     : BOOL;
    bErr      : BOOL;
    nErrId    : UDINT;
END_VAR | Name | Type | Description | 
|---|---|---|
| bBusy | BOOL | This output remains TRUE until the function block has executed a command, but at the longest for the duration supplied to the 'Timeout' input. While Busy = TRUE, no new command will be accepted at the inputs. Please note that it is not the execution of the service but its acceptance whose time is monitored. | 
| bErr | BOOL | This output is switched to TRUE as soon as an error occurs during the execution of a command. The command-specific error code is contained in 'nErrId'. Is reset to FALSE by the execution of a command at the inputs. | 
| nErrId | UDINT | Contains the command-specific error code of the most recently executed command. Is reset to 0 by the execution of a command at the inputs. The error numbers in ErrId can be looked up in the ADS error documentation or in the NC error documentation (error codes above 0x4000). | 
See also:
Requirements
| Development environment | Target platform | PLC libraries to be linked | 
|---|---|---|
| TwinCAT v3.1.0 | PC or CX (x86 or x64) | Tc2_NCI |