ItpSetSubroutinePath

ItpSetSubroutinePath 1:

With function block ItpSetSubroutinePath , the search path for subroutines can optionally be set.

If a subroutine still has to be integrated, the file is searched in the following order:

Only one optional path can be active at a time and it will remain active until it is overwritten with:

After a TwinCAT restart, the path has to be re-assigned.

ItpSetSubroutinePath 2:

Outdated version

The sole purpose of the function block is to ensure compatibility with existing projects. For new projects please use the function block ItpSetSubroutinePathEx.

ItpSetSubroutinePath 3: Inputs

VAR_INPUT
    bExecute       : BOOL;
    nChnId         : UDINT;
    sPath          : STRING;
    nLength        : UDINT;
    tTimeOut       : TIME;
END_VAR

Name

Type

Description

bExecute

BOOL

The command is triggered by a rising edge at this input.

nChnId

UDINT

Channel ID

sPath

STRING

Optional path for subroutines; is disabled with an empty string.

nLength

UDINT

String length

tTimeOut

TIME

ADS Timeout-Delay

ItpSetSubroutinePath 4: Outputs

VAR_OUTPUT
    bBusy     : BOOL;
    bErr      : BOOL;
    nErrId    : UDINT;
END_VAR

Name

Type

Description

bBusy

BOOL

This output remains TRUE until the function block has executed a command, but at the longest for the duration supplied to the 'Timeout' input. While Busy = TRUE, no new command will be accepted at the inputs. Please note that it is not the execution of the service but its acceptance whose time is monitored.

bErr

BOOL

This output is switched to TRUE as soon as an error occurs during the execution of a command. The command-specific error code is contained in 'nErrId'. Is reset to FALSE by the execution of a command at the inputs.

nErrId

UDINT

Contains the command-specific error code of the most recently executed command. Is reset to 0 by the execution of a command at the inputs. The error numbers in ErrId can be looked up in the ADS error documentation or in the NC error documentation (error codes above 0x4000).

Requirements

Development environment

Target platform

PLC libraries to be linked

TwinCAT v3.1.0

PC or CX (x86 or x64)

Tc2_NCI