ItpLoadProgEx
The ItpLoadProgrEx function block loads the desired NC program.
The text file containing the NC program must be coded in ANSI or UTF-8 format. Other text encodings (e.g. UTF-8-BOM) may contain hidden special characters that lead to syntax errors.
If no file path is specified, the NC program is searched for in the default directory.
This is from TwinCAT 3.1 Build 4026:
C:\ProgramData\Beckhoff\TwinCAT\Mc\Nci
and for previous versions: C:\TwinCAT\Mc\Nci.
Inputs
VAR_INPUT
bExecute : BOOL;
sPrg : STRING(255);
nLength : UDINT;
tTimeOut : TIME;
END_VARName | Type | Description |
|---|---|---|
bExecute | BOOL | The function block reads the NC program when a rising edge is encountered. |
sPrg | STRING(255) | Name of the NC program that is loaded. |
nLength | UDINT | String length of the program name |
tTimeOut | TIME | ADS Timeout-Delay |
/
Inputs/Outputs
VAR_IN_OUT
sNciToPlc : NCTOPLC_NCICHANNEL_REF;
END_VAR Name | Type | Description |
|---|---|---|
sNciToPlc | NCTOPLC_NCICHANNEL_REF | The structure of the cyclic channel interface from the NCI to the PLC. This structure is read-only (type: NCTOPLC_NCICHANNEL_REF). |
Outputs
VAR_OUTPUT
bBusy : BOOL;
bErr : BOOL;
nErrId : UDINT;
END_VAR Name | Type | Description |
|---|---|---|
bBusy | BOOL | This output remains TRUE until the function block has executed a command, but at the longest for the duration supplied to the 'Timeout' input. While Busy = TRUE, no new command will be accepted at the inputs. Please note that it is not the execution of the service but its acceptance whose time is monitored. |
bErr | BOOL | This output is switched to TRUE as soon as an error occurs during the execution of a command. The command-specific error code is contained in 'nErrId'. Is reset to FALSE by the execution of a command at the inputs. |
nErrId | UDINT | Contains the command-specific error code of the most recently executed command. Is reset to 0 by the execution of a command at the inputs. The error numbers in ErrId can be looked up in the ADS error documentation or in the NC error documentation (error codes above 0x4000). |
Example
VAR
in_stItpToPlc AT %I* : NCTOPLC_NCICHANNEL_REF;
fbLoadProg : ItpLoadProgEx;
sProgramPath : STRING (255):= 'TestIt.nc';
END_VARfbLoadProg(
bExecute := TRUE,
sPrg := sProgramPath,
nLength := LEN(sProgramPath),
tTimeOut := t#200ms,
sNciToPlc := in_stItpToPlc
);Requirements
|
Development environment |
Target platform |
PLC libraries to be linked |
|---|---|---|
|
TwinCAT v3.1.0 |
PC or CX (x86 or x64) |
Tc2_NCI |