ItpIsFastMFunc

The function ItpIsFastMFunc determines whether the fast M-function is set for the supplied M-function number.
Inputs
FUNCTION ItpIsFastMFunc
VAR_IN
nFastMFuncNo : INT;
END_VARName | Type | Description |
|---|---|---|
nFastMFuncNo | BOOL | Number of the M-function that is to be checked. |
/
Inputs/Outputs
VAR_IN_OUT
sNciToPlc : NCTOPLC_NCICHANNEL_REF;
END_VAR Name | Type | Description |
|---|---|---|
sNciToPlc | NCTOPLC_NCICHANNEL_REF | The structure of the cyclic channel interface from the NCI to the PLC. This structure is read-only (type: NCTOPLC_NCICHANNEL_REF). |
Return value
Name | Type | Description |
|---|---|---|
ItpIsFastMFunc | BOOL | The function returns TRUE if the fast bit of the M-function is set. |
![]() | ItpIsFastMFunc evaluates the variable 'nFastMFuncMask' from the cyclic interface. |
Example
(*this enum is defined by the user *)
TYPE FastMFuncs:
(
M10_CoolingFluidOn := 10, (*fast M-Funktion M10*)
M11_CoolingFluidOff := 11,
M12_FanOn := 12,
M13_FanOff := 13
);
END_TYPE VAR
sNciToPlc AT%I*: NCTOPLC_NCICHANNEL_REF
enFastMFuncs : FastMFuncs;
bTurnFanOn : BOOL;
END_VAR Requirements
|
Development environment |
Target platform |
PLC libraries to be linked |
|---|---|---|
|
TwinCAT v3.1.0 |
PC or CX (x86 or x64) |
Tc2_NCI |