Limit Switches
The Limit Switches parameters can be set under MOTION | NC-Task 1 SAF | Axes | Axis 1 | Parameter.
Alternatively, the Limit Switches parameters can be set under MOTION | NC-Task 1 SAF | Axes | Axis 1 | Enc | Parameter.
Similar for other identifiers.
Soft Position Limit Minimum Monitoring

FALSE
: Soft Position Limit Minimum Monitoring is not enabled.
TRUE
: Soft Position Limit Minimum Monitoring is enabled.
Minimum Position
Position lower limit for the axis, which must not be violated when Soft Position Limit Minimum Monitoring is enabled. Commands that violate this lower limit will be rejected.
Soft Position Limit Maximum Monitoring

FALSE
: Soft Position Limit Maximum Monitoring is not enabled.
TRUE
: Soft Position Limit Maximum Monitoring is enabled.
Maximum Position
Position upper limit for the axis, which must not be violated when Soft Position Limit Maximum Monitoring is enabled. Commands that violate this upper limit will be rejected.