Simulation Axis
In the following section you will find out how to set up an NC axis as a simulation axis.
A simulation axis is not linked with drive hardware via the IO configuration.
Axis type
Settings dialog:
Settings for an NC simulation axis that is linked with the PLC axis variable axis
in the program MAIN
:

[1]
| Select this entry.
|
[2] | Remains empty. |
Setting up a simulation axis
- 1. In the axis level, select the NC axis that you wish to set up as a simulation axis.
- 2. Open the Settings dialog for this NC axis.
- 3. In the drop-down box for the axis type, select the entry Standard (Mapping via Encoder and Drive) [1].
- 4. For a simulation axis the entry Link To I/O… [2] remains empty.
- You have set up the NC axis as a simulation axis.
Further information
- Creating a PLC axis variable: Motion Control in the PLC project
- Adding an NC axis: Inserting an NC configuration
- Linking an NC axis with a PLC axis variable: "Link To PLC…" button