FB_TextToSpeech
Text to Speech function block.
Syntax
Definition:
FUNCTION_BLOCK FB_TextToSpeech
VAR_INPUT
bSpeak : BOOL;
sUtterance : STRING;
nConfigurationId : UINT;
nLanguageId : UINT;
END_VAR
VAR_OUTPUT
bBusy : BOOL;
bError : BOOL;
nErrorId : ETcsSpeechCommandExitCode;
nLastCommandExitCode : UINT;
nPlaybackPosition : ULINT;
nPlaybackTotal : ULINT;
END_VAR
Inputs
Name | Type | Description |
|---|---|---|
bSpeak | BOOL | Rising edge starts a speech command. |
sUtterance | STRING | Utterance for the speech command |
nConfigurationId | UINT | ConfigurationID to be used for output (see TcSpeech Configurator) |
nLanguageId | UINT | LanguageId which is to be used. '0' for configured default language. |
Outputs
Name | Type | Description |
|---|---|---|
bBusy | BOOL | Function block is busy. |
bError | BOOL | Function block is in error state. |
nErrorId | ErrorId, which indicates the exact reason for the error. | |
nLastCommandExitCode | UINT | Return value of the last call. |
nPlaybackPosition | ULINT | Current position of the speech output. |
nPlaybackTotal | ULINT | Total length of the speech output. |
Methods
Name | Description |
|---|---|
Method to specify a different AmsNetAdr for the TcSpeech service. Only needs to be called up once. |
Required License
TC3 Speech