Creating a configuration
TwinCAT Speech is parameterized via its own configuration project in TwinCAT Engineering. New TwinCAT Speech configurations are created as follows:
- 1. Open TwinCAT Engineering and create a new project.
 - 2. Select an empty TwinCAT Controller project, name it, and click OK.

 - The new TwinCAT Controller project opens.
 - 3. Right-click the new TwinCAT Controller project.
 - 4. Select Add>New Item.

 - The Add New Item window opens.
 - 5. Select TwinCAT Speech Configurator, name the configuration, and click Add.

 - The start window for the TwinCAT Speech configuration opens.
 - 6. Select the desired target system.
 - Assignment to a target system is important for TwinCAT Speech, because the hardware configuration of the sound cards is individual.
 
- A new TwinCAT Speech configuration has now been created.