SumUp
The SumUp subfolder contains low-level blocks that allow writing or reading multiple ADS symbols with one API call. Compared to simple ADS Read or Write statements, only one handle is needed for writing or reading multiple symbols with the SumUp. The handle can in turn contain several subcommands that are sent simultaneously to the TwinCAT 3 Runtime.

Init SumUp
The block Init SumUp initializes the ADS SumUp. If the call is successful, the block returns a handle to the ADS SumUp.

Input/output | Meaning |
|---|---|
[0] [4] Handle | Handle to the client |
[1] bAutosend | Autosend flag enables automatic sending of the SubCommand |
[5] SumUp mode | SumUp modes:
|
[6] SumUp handle | Handle on the SumUp |
Add SubCommand
The block Add SubCommand initializes a new subcommand and adds it to the SumUp handle.

Input/output | Meaning |
|---|---|
[0] [4] Handle | Handle to the client |
[5] [6] SumUpHandle | Handle on the SumUp |
[7] [8] Symbol | ADS symbol consisting of AMS address and symbol designation:
Examples of the symbol name:
|
Put Data
The block Put Data adds new data to the initialized sub-command. For this, the block needs the symbol name to identify the sub-command. The block can only be used for writing SumUp commands.

Input/output | Meaning |
|---|---|
[0] [4] Handle | Handle to the client. |
[5] [6] SumUpHandle | Handle on the SumUp |
[7] Symbol | ADS symbol consisting of AMS address and symbol designation:
Examples of the symbol name:
|
[9] WriteData | Data that is to be written |
Get Data
The block Get Data retrieves new data from the initialized sub-command. For this, the block needs the symbol name to identify the sub-command. The block can only be used for reading SumUp commands.

Input/output | Meaning |
|---|---|
[0] [4] Handle | Handle to the client |
[5] [6] SumUpHandle | Handle on the SumUp |
[7] Symbol | ADS symbol consisting of AMS address and symbol designation:
Examples of the symbol name:
|
[9] Wait? | Wait flag that defines whether to wait for the data to be read.
|
[15] Read Data | The data to be read |
Enable Autosend
The block Enable Autosend enables the automatic sending of the SumUp command.

Input/output | Meaning |
|---|---|
[0] [4] Handle | Handle to the client |
[1] bAutosend | The Autosend flag enables automatic sending of the SubCommand |
[5] [6] SumUpHandle | Handle on the SumUp |
Notice | |
Sub-commands without data Automatic sending fails for initialized sub-commands that do not contain any data. |
Send
The Send block sends the sub-commands added to the SumUp handle to the TwinCAT 3 runtime. In contrast to Enable Autosend, the Send SumUp must be explicitly called cyclically to send the data to TwinCAT.

Input/output | Meaning |
|---|---|
[0] [4] Handle | Handle to the client |
[5] [6] SumUpHandle | Handle on the SumUp |
Notice | |
Sub-commands without data Sending fails for initialized sub-commands that do not contain any data. |
Release SumUp
The block Release SumUp releases the SumUp handle from memory.

Input/output | Meaning |
|---|---|
[0] [4] Handle | Handle to the client |
[5] SumUpHandle | Handle on the SumUp |