Write
The subfolder Write contains low-level blocks that are necessary for writing via ADS.
Init Writer
The Init Writer block initializes the ADS writer. When a call is successful the block returns a handle to the ADS writer.

Input/output | Meaning |
|---|---|
[0] [4] Handle | Handle to the ADS client |
[5] [6] SymbolName | Describes an ADS symbol consisting of AMS address and symbol designation:
Examples of the symbol name:
|
[7] [8] WriterMode | Writing mode (Sync/Async) |
[10] WriteHandle | Handle to the ADS Writer |
Send Writer Request
The Send Writer-Request block sends a write request to the ADS server. The block waits for a response from the server if the writer has been initialized with the "Synchronous" operation mode. Otherwise the block does not wait for the response and passes the WriteHandle.

Input/output | Meaning |
|---|---|
[0] [4] Handle | Handle to the ADS client |
[5] [6] SymbolName | Describes an ADS symbol consisting of AMS address and symbol designation:
Examples of the symbol name:
|
[7] WriterMode | Writing mode (Sync/Async) |
[8] [9] WriteHandle | Handle to the ADS Writer |
[12] ADS-Write Data | TypeResolved ADS data packet |
[10] Write status? | Write status |
CheckWriteStatus
The CheckWriteStatus block checks for successful write access to the ADS server in connection with the "Asynchronous" operation mode.

Input/output | Meaning |
|---|---|
[0] [4] Handle | Handle to the ADS client |
[5] SymbolName | Describes an ADS symbol consisting of AMS address and symbol designation:
Examples of the symbol name:
|
[6] [9] WriteHandle | Handle to the ADS Writer |
[8] Write status? | Write status |
Release Writer
The Release Writer releases the handle to the writer from memory.

Input/output | Meaning |
|---|---|
[0] [4] Handle | Handle to the ADS client |
[5] WriteHandle | Handle to the ADS Writer |