Return codes
Return codes of the ipResultMessage.
Online Watch:

Defined events:
nEventId (hex) | Name | sEventText |
---|---|---|
16#0001 | DbgMessage | Dbg: {0}. |
|
|
|
16#1001 | TcCom_Transition_PS_Failed | Error in Transition PREOP->SAFEOP. |
16#1002 | TcCom_Transition_SO_Failed | Error in Transition SAFEOP->OP. |
16#1003 | TcCom_Transition_SO_Failed_NoTask | Error in Transition SAFEOP->OP: No Task assigned. Module will not be executed cyclically. |
16#1004 | TcCom_Transition_OS_Failed | Error in Transition OP->SAFEOP. |
16#1005 | TcCom_Transition_SP_Failed | Error in Transition SAFEOP->PREOP. |
16#1006 | TcCom_CyclicCallerAssigned | Cyclic caller is assigned. Methods can not be called. |
16#1007 | TcCom_InvalidObjectState | Invalid object state. |
16#1008 | TcCom_InvalidSymbolSize | Invalid symbol size. |
16#1009 | TcCom_InvalidDataAreaNo | Invalid data area number. |
|
|
|
16#2001 | Init_NoRouterMemory | Memory could not be allocated dynamically. Check size of rotuer memory. |
|
|
|
16#3001 | Config_InvalidPointer | Null pointer was allocated. |
16#3002 | Config_NoRouterMemory | Memory could not be allocated dynamically. Check size of rotuer memory. |
16#3003 | Config_InvalidCutOff | Cutoff must be greater than zero and smaller than Samplingrate/2. |
16#3004 | Config_InvalidSamplingRate | Sampling rate must be greater than zero. |
16#3005 | Config_InvalidSamplesToFilter | SamplesToFilter must be greater than zero. |
16#3008 | Config_InvalidOrder | Order must be greater than zero and smaller than eleven. |
16#3009 | Config_InvalidWindowLength | WindowLength must be greater than zero. |
16#3010 | Config_InvalidThreshold | Threshold must be equal or greater than zero. |
16#3011 | Config_InvalidMaxStd | MaxStd must be equal or greater than zero. |
16#3012 | Config_InvalidMaxWeightDeviation | MaxWeightDeviation must be equal or greater than zero. |
16#3013 | Config_InvalidReferenceValue | ReferenceHigh must be greater than ReferenceLow. |
16#3014 | Config_InvalidRawValue | RawHigh must be greater than RawLow. |
16#3015 | Config_InvalidCalibrationValues | RawHigh must be greater than RawLow. ReferenceHigh must be greater than ReferenceLow. |
16#3016 | Config_InvalidRelativeWeightLimit | RelativeWeightLimit must be greater or equal than zero and smaller than one. |
16#3017 | Config_InvalidNotchFrequency | NotchFrequency must be greater than zero and smaller than fSamplingrate/2. |
|
|
|
16#4001 | Run_MissingConfiguration | Missing configuration. |
16#4002 | Run_InvalidPointer | Null pointer was allocated. |
16#4003 | Run_InvalidInputSize | Invalid input size. |
16#4004 | Run_InvalidOutputSize | Output size array cant be smaller than input array size. |
|
|
|
16#6001 | Warning_CalibrationProcessFailed | Calibration has not been processed successfully. RawHigh must be greater than RawLow. ReferenceHigh must be greater than ReferenceLow. |
16#6002 | Warning_CouldNotTriggerTare | The tare process could not be triggered because the calibration process had not yet been completed. |
16#6003 | Warning_InvalidState | Invalid state. |
|
|
|
16#7003 | Warning_InvalidCutOff | Cutoff must be greater than zero and smaller than Samplingrate/2. |
16#7004 | Warning_InvalidSamplingRate | Sampling rate must be greater than zero. |
16#7005 | Warning_InvalidSamplesToFilter | SamplesToFilter must be greater than zero. |
16#7008 | Warning_InvalidOrder | Order must be greater than zero and smaller than eleven. |
16#7009 | Warning_InvalidWindowLength | WindowLength must be greater than zero. |
16#7010 | Warning_InvalidThreshold | Threshold must be equal or greater than zero. |
16#7011 | Warning_InvalidMaxStd | MaxStd must be equal or greater than zero. |
16#7012 | Warning_InvalidMaxWeightDeviation | MaxWeightDeviation must be equal or greater than zero. |
16#7013 | Warning_InvalidReferenceValue | ReferenceHigh must be greater than ReferenceLow. |
16#7014 | Warning_InvalidRawValue | RawHigh must be greater than RawLow. |
16#7015 | Warning_InvalidCalibrationValues | RawHigh must be greater than RawLow. ReferenceHigh must be greater than ReferenceLow. |
16#7016 | Warning_InvalidNotchFrequency | NotchFrequency must be greater than zero and smaller than fSamplingrate/2. |