Statistical methods
This sample illustrates the options for statistical evaluation of Condition Monitoring Library data. Statistical evaluations for standard normal and gamma-distributed signal data and a sine signal are processed. The function blocks FB_CMA_HistArray, FB_CMA_EmpiricalMean, FB_CMA_EmpiricalStandardDeviation, FB_CMA_EmpiricalSkew and FB_CMA_EmpiricalExcess are used.
The sample is available for download from here:
Block diagram
![Statistical methods 1:](Images/png/5260536331__Web.png)
Program parameters
The table below shows a list of important parameters for the configuration of the function blocks that are used.
Buffer size | 100 |
Channels | 3 |
Frequency bins | 200 |
Requirements
Development environment | Target platform | PLC libraries to include |
---|---|---|
TwinCAT v3.1.4022 | PC or CX (x86, x64) | Tc3_CM (>= 1.0.22), Tc3_CM_Base (>= 1.1.10), Tc3_MultiArray |