Dashboard Configuration
HMI Dashboard tab
The HMI Dashboard tab contains all the configurations for the dashboard.

Configuration
HMI generation Settings
Generate HMI Dashboard | Enables the generation of the HMI Dashboard, if enabled. This automatically activates/deactivates the checkboxes Create Bootproject and Activate PLC Runtime on the TwinCAT PLC Target tab. |
Create only HMI Project (No PLC) | Creates only one HMI project and not a PLC project, if enabled. |
HMI Project Name | Name of the TwinCAT HMI project. |
Dashboard version | Selection of the dashboard version. |
Dashboard Options
Dashboard Title | Title of the HMI Dashboard, which is displayed in the dashboard header. |
Desktop Height | Height of the target screen in pixels. |
Desktop Width | Width of the target screen in pixels. |
Create Startpage | Creates a start page for the dashboard that displays a map with all machine locations. The location data is adopted from the machine management data. |
Show current time | Creates a clock in the dashboard header that shows the current local time. |
Dashboard Styles
Dashboard Layout | Defines the layout of the dashboard. Dock requires the "Dock" property of a module to be TRUE. Dock Left: fixed left column |
Dashboard Sorting | Defines the sorting of the dashboard. Space Saving: arranges the controls without free space. |
Dashboard Theme | Defines the topic of the HMI dashboard, affects controls and backgrounds: Light: bright skin, especially for day mode. |
Select Color | Defines the color of the dashboard header with color gradient, if enabled. |
Control Style | Defines the style of the controls: Round: the controls have rounded corners. |
Change default background image | If enabled, a customer-specific background image can be set for the HMI Dashboard. If nothing is defined, the default image is used. |
Use Logo | If enabled, a logo is added to the dashboard header. A customer-specific image can be defined for the logo. |
Use custom Map Icon | If enabled, a customer-specific map icon can be defined for the map on the start page. If nothing is defined, the default icon is used. |
Languages
Languages | Enables the enabled language for the language change in the HMI Dashboard. (Only for standard text) |
HMI Server
Publishes the dashboard to a TwinCAT HMI server, if enabled. | |
Address | Enter the IP address or host name of the TwinCAT HMI server. |
Port | Enter the port of the TwinCAT HMI Server (by default 1010 without encryption and 1020 with encryption). |
User | Enter the user name. |
Password | Enter the password. (The administrator password must be set on the server via the configuration page). |
Validate Connection | Press the button to validate your server connection. |
![]() | In order to publish to a remote HMI server, the HMI port and IP of the development computer must be shared in the HMI server. Also an inbound rule with the HMI ports must be set up in the Windows firewall from the remote PC. |
Visual Studio tab
On the Visual Studio tab you can select which version of Visual Studio® or TwinCAT XAE shell is to be used to generate PLC and HMI. In addition, it is possible to generate HMI and PLC in two different solutions.

Keep Visual Studio open | Keeps Visual Studio® open after the generation, if checked. |
Target VS Version | The target Visual Studio® version for PLC and HMI. |
Create HMI in another Visual Studio | If enabled, the HMI is generated into a second solution. A different Visual Studio® version can be selected. |
Requirement: TwinCAT or TwinCAT HMI must be installed in the selected Visual Studio® version. |
Click Next to display the Summary tab, then click Deploy to start generating the dashboard.
Impressions
Topics



Styles



Views for mobile devices


Map on customer-specific dashboard


Historical data and machine switching


