Configure
Configure the algorithm.
Syntax
Definition:
METHOD Configure : BOOL
VAR_INPUT
nNumValues : UDINT;
eStartupBehaviour : E_ALY_MovingAvgStartupBehaviour;
END_VAR
Inputs
Name | Type | Description |
|---|---|---|
nNumValues | ULINT | Number of values included in the calculation of the moving average. |
eStartupBehaviour | Calculation behavior at the beginning of the analysis with less values than configured in Num Values. ZeroPadding: The missing values are filled with zeros. UseFirstValue: The first value is used until the number of values equals Num Values. WaitUntilFilled: The first result is calculated when the number of values equals Num Values. AvgOverExisting: The average is calculated with the already existing values until the number of values equals Num Values. |
Return value
Name | Type | Description |
|---|---|---|
Configure | BOOL | Returns |