Time Clock 1Ch

Time Clock 1Ch 1:

Time Clock 1Ch executes a timer which can be configured with switch-on time, switch-off time and the days of the week on which the time switch should be active. A timestamp is required as a reference value because the algorithm needs a time context in which to operate. This reference timestamp is automatically set if the configuration includes another algorithm. Therefore it is not possible to use the Time Clock 1Ch individually.

Optionally, a Boolean signal can be selected for the Enable Execution input so that the algorithm is only active if the value of the selected signal is TRUE.

Configuration options

Output Values

Standard HMI Controls

For the Timer Clock 1Ch algorithm, the following HMI controls are available for generating an Analytics Dashboard:

1. The Timer Control visualizes the output value Next Switch.

Time Clock 1Ch 2:

2. The Table Control or Multivalue Control visualizes all output values: Output, Next Switch.

Time Clock 1Ch 3:
Time Clock 1Ch 4:
Time Clock 1Ch 5:

Alternatively, customer-specific HMI controls can be mapped in the Timer Clock 1Ch algorithm using the Mapping Wizard.