eventFilter
Event filter
General Information
|
Domain |
TcHmiSrv |
Schema
|
Type |
array |
JSON Schema
{
"description": "descEventFilter",
"items": {
"anyOf": [
{
"properties": {
"comparator": {
"enum": [
"==",
"!=",
"contains",
"contains not",
"== [ignore case]",
"!= [ignore case]",
"contains [ignore case]",
"contains not [ignore case]"
],
"type": "string"
},
"path": {
"enum": [
"domain",
"sourceDomain",
"name",
"text",
"sessionId"
],
"type": "string"
},
"value": {
"type": "string"
}
},
"required": [
"path",
"comparator",
"value"
],
"type": "object"
},
{
"properties": {
"comparator": {
"enum": [
"==",
"!=",
"<",
">",
"<=",
">="
],
"type": "string"
},
"path": {
"enum": [
"id"
],
"type": "string"
},
"value": {
"type": "number"
}
},
"required": [
"path",
"comparator",
"value"
],
"type": "object"
},
{
"properties": {
"comparator": {
"enum": [
"==",
"!=",
"<",
">",
"<=",
">="
],
"type": "string"
},
"path": {
"enum": [
"timeRaised"
],
"type": "string"
},
"value": {
"format": "date-time",
"type": "string"
}
},
"required": [
"path",
"comparator",
"value"
],
"type": "object"
},
{
"properties": {
"comparator": {
"enum": [
"==",
"!=",
"<",
">",
"<=",
">="
],
"type": "string"
},
"path": {
"enum": [
"timeCleared",
"timeConfirmed"
],
"type": "string"
},
"value": {
"$ref": "tchmi:server#/definitions/nullableDateTime"
}
},
"required": [
"path",
"comparator",
"value"
],
"type": "object"
},
{
"properties": {
"comparator": {
"enum": [
"==",
"!=",
"<",
">",
"<=",
">="
],
"type": "string"
},
"path": {
"enum": [
"type"
],
"type": "string"
},
"value": {
"enum": [
0,
1
],
"options": [
{
"label": "ENUM_0_MESSAGE",
"value": 0
},
{
"label": "ENUM_1_ALARM",
"value": 1
}
],
"type": "integer"
}
},
"required": [
"path",
"comparator",
"value"
],
"type": "object"
},
{
"properties": {
"comparator": {
"enum": [
"==",
"!=",
"<",
">",
"<=",
">="
],
"type": "string"
},
"path": {
"enum": [
"severity"
],
"type": "string"
},
"value": {
"$ref": "tchmi:server#/definitions/severity"
}
},
"required": [
"path",
"comparator",
"value"
],
"type": "object"
},
{
"properties": {
"comparator": {
"enum": [
"==",
"!=",
"<",
">",
"<=",
">="
],
"type": "string"
},
"path": {
"enum": [
"alarmState"
],
"type": "string"
},
"value": {
"$ref": "tchmi:server#/definitions/alarmState"
}
},
"required": [
"path",
"comparator",
"value"
],
"type": "object"
},
{
"properties": {
"comparator": {
"enum": [
"==",
"!=",
"<",
">",
"<=",
">="
],
"type": "string"
},
"path": {
"enum": [
"confirmationState"
],
"type": "string"
},
"value": {
"$ref": "tchmi:server#/definitions/confirmationState"
}
},
"required": [
"path",
"comparator",
"value"
],
"type": "object"
},
{
"properties": {
"comparator": {
"enum": [
"==",
"!="
],
"type": "string"
},
"path": {
"enum": [
"isActive"
],
"type": "string"
},
"value": {
"type": "boolean"
}
},
"required": [
"path",
"comparator",
"value"
],
"type": "object"
},
{
"properties": {
"comparator": {
"enum": [
"==",
"!=",
"<",
">",
"<=",
">=",
"contains",
"contains not",
"== [ignore case]",
"!= [ignore case]",
"contains [ignore case]",
"contains not [ignore case]"
],
"type": "string"
},
"path": {
"pattern": "^params::",
"type": "string"
},
"value": {
"oneOf": [
{
"type": "string"
},
{
"type": "number"
},
{
"type": "boolean"
}
]
}
},
"required": [
"path",
"comparator",
"value"
],
"type": "object"
},
{
"properties": {
"logic": {
"enum": [
"AND",
"OR"
],
"type": "string"
}
},
"required": [
"logic"
],
"type": "object"
},
{
"$ref": "tchmi:server#/definitions/eventFilter"
}
]
},
"type": "array"
}