CellOptions

Definition for the cells.

Here you can define a specific property for each cell. In each definition a row and column index defines which cell is to be addressed.

You can define:

Engineering

You can change the cell settings with this dialog.

Items

List of all objects added

CellOptions 1:

Delete the selected object

CellOptions 2:

Change the object order (top = left)

CellOptions 3:

Add a new object

Category: Colors

Name

Description

BackgroundColor

Definition of the background color

BorderColor

Definition of the border color of the control

BorderColor

Definition of the border color of the control

BorderRadius

Definition of the radius of the four corners to round them off

BorderStyle

Selection of the border style of the four sides of the control

BorderWidth

Definition of the border width of the four sides of the control

Category: Background Image

Name

Description

BackgroundImage

Definition of an image that is located above the background color

BackgroundImageHeight

Definition of the height of the background image

BackgroundImageHeightUnit

Selection of the unit of the height of the background image:

  • Pixels for an absolute height
  • Percent for a relative height

BackgroundImageWidth

Definition of the width of the background image

BackgroundImageWidthUnit

Selection of the unit of the width of the background image:

  • Pixels for an absolute width
  • Percent for a relative width

BackgroundImagePadding

Definition of an additional distance between the border of the control and background image for the four sides

BackgroundImageVerticalAlignment

Definition of the vertical alignment of the background image within the control

BackgroundImageHorizontalAlignment

Definition of the horizontal alignment of the background image within the control

BackgroundImageWidth

Definition of the width of the background image

BackgroundImageWidthUnit

Selection of the unit of the width of the background image:

  • Pixels for an absolute width
  • Percent for a relative width

BackgroundImageHeight

Definition of the height of the background image

BackgroundImageHeightUnit

Selection of the unit of the height of the background image:

  • Pixels for an absolute height
  • Percent for a relative height

BackgroundImageHorizontalAlignment

Definition of the horizontal alignment of the background image within the control

BackgroundImageVerticalAlignment

Definition of the vertical alignment of the background image within the control

BackgroundImagePadding

Definition of an additional distance between the border of the control and background image for the four sides

Category: Border

Name

Description

Border Width

Definition of the border width of the four sides of the cell

Border Style

Selection of the border style of the four sides of the cell

Category: Layout

Name

Description

Grid Column Index

Definition of the column of a grid that is to be defined by the cell option

Grid Row Index

Definition of the row of a grid that is to be defined by the cell option

Padding

Definition of an additional distance between the cell border and the controls added to the cell for the four sides

Schema (version 1.8): tchmi:framework#/definitions/CellOptions

Schema (version 1.12): tchmi:framework#/definitions/TcHmi.Controls.System.TcHmiGrid.CellOptions

Attribute getter

public getCellOptions(): TcHmi.Controls.System.TcHmiGrid.ICellOptions[] | undefined;

Parameter

Name

Type

Description

-

-

-

Return value

Type

Description

TcHmi.Controls.System.TcHmiGrid.ICellOptions[], undefined

The current value of the attribute.

Attribute setter

public setCellOptions(valueNew: TcHmi.Controls.System.TcHmiGrid.ICellOptions[] | null): void;

Parameter

Name

Type

Description

valueNew

TcHmi.Controls.System.TcHmiGrid.ICellOptions[], null

The new value of the attribute. If null is passed, the internal default value is used.

Return value

Type

Description

void

No return value.

CellOptions 4:

Available from 1.8