Columns

Description of the columns and the data format

Schema: tchmi:framework#/definitions/TcHmi.Controls.Beckhoff.TcHmiTreeView.ColumnDefinitionList

Attribute getter


public getColumns(): TcHmi.Controls.Beckhoff.TcHmiTreeView.Column[] | TcHmi.Controls.Beckhoff.TcHmiTreeView.SimpleColumn | null;

Parameter

Name

Type

Description

-

-

-

Return value

Type

Description

TcHmi.Controls.Beckhoff.TcHmiTreeView.Column[],TcHmi.Controls.Beckhoff.TcHmiTreeView.SimpleColumn, null

The current value of the attribute.

Attribute setter


public setColumns (valueNew: TcHmi.Controls.Beckhoff.TcHmiTreeView.Column[] | TcHmi.Controls.Beckhoff.TcHmiTreeView.SimpleCoumn | null): void;

Parameter

Name

Type

Description

valueNew

TcHmi.Controls.Beckhoff.TcHmiTreeView.Column[],TcHmi.Controls.Beckhoff.TcHmiTreeView.SimpleColumn, null

The new value of the attribute. If null is passed, the internal default value is used.

Return value

Type

Description

void

No return value.

Columns 1:

Available since version 1.12.760