Add handwritten signature

Server Extension configuration.

1. Open the configuration page.
2. Go to the configuration of TcHmiReporting.
3. Open the path. If not available, create the path Runtimes/{Runtimename}/Configurations/{Configuration name}/Signature configuration.
4. Enter a name for the signature configuration.
5. Enable Use handwritten signature
The signature is now integrated.
6. Open the path. If not available, create the path Runtimes/{Runtimename}/Configurations/{Configuration name}/Settings for handwritten signatures.
7. Click on Add to create a new configuration and enter the following values:
Signature name: Name of the configuration (must be identical to the name of the signature configuration)
Owner: Name of the person to whom the signature belongs
Location: Location of the creation
Height: Height of the image
Width: Width of the image
Align bottom: Distance to the bottom edge
Align left: Distance to the left edge
Signature image: Image file of the signature.
The configuration of the signature is now complete. The signature is now added to the PDF when it is generated.
Add handwritten signature 1:
8. Switch to the User-defined configuration tab.
9. Create a new report.
10. Open the newly created PDF file with Acrobat Reader.
A banner indicating the signature contained will appear at the top.