Adding symbols
Use Symbols to add new entries to the Audit Trail. Here it is only possible to log write commands from the client to the server. If there is a write command from a symbol added to the Audit Trail, the value change is logged in the Audit Trail together with the user and timestamp.
Adding a symbol in Visual Studio / TcXaeShell
- 1. Open the TwinCAT HMI Configuration window.
- 2. Go to the Server Symbols / Mapped Symbols tab.
- 3. Select the symbols to be added to the Audit Trail.
- 4. Add these to the Audit Trail configuration by right-clicking on Audit Trail Settings.
- A pop-up opens for further settings.
- 5. Define whether symbol monitoring is active and a comment must be entered when writing.
- The symbols you have configured are now automatically logged in the Audit Trail during a write operation. If the comment function has been activated, this is also entered.
Adding a symbol via the server configuration page
- 1. Open the server configuration page.
- 2. Go to the TcHmiAuditTrail / General tab.
- 3. Go to Activated symbols.
- All currently configured symbols are displayed here.
- 4. Click on Add to create a new symbol.
- 5. Enter the corresponding symbol for the name.
- 6. Set Active to true so that the selected symbol is included in Audit Trail.
- 7. Set Comment required to true so that a comment must be entered during the writing process.
- The symbols you have configured are now automatically logged in the Audit Trail during a write operation.