RecursiveResolveHandler.T. Class

Provides methods to handle resolving instances of a specified type.
Instances of the specified type consist only of other instances of the specified type, like the Value class without Alarms, Events and Messages.

Inheritance Hierarchy

System.Object
  TcHmiSrv.Core.Tools.Resolving.Handlers.ResolveHandler.T.
    TcHmiSrv.Core.Tools.Resolving.Handlers.RecursiveResolveHandler.T.
Namespace:  TcHmiSrv.Core.Tools.Resolving.Handlers
Assembly:  TcHmiSrvExtNet.Core (in TcHmiSrvExtNet.Core.dll) Version: 1.3.0.0

Syntax

C#

public class RecursiveResolveHandler<T> : ResolveHandler<T>

Type Parameters

T

The type of the instances to resolve.

The RecursiveResolveHandler.T. type exposes the following members.

Constructors

 

Name

Description

RecursiveResolveHandler.T. Class 1:

RecursiveResolveHandler.T.

Initializes a new instance of the RecursiveResolveHandler.T. class with the specified RecursiveResolver.T..

Properties

 

Name

Description

RecursiveResolveHandler.T. Class 2:

CanRead

Gets a value that indicates whether this ResolveHandler.T. can read elements.
The default value is true. (Inherited from ResolveHandler.T..)

RecursiveResolveHandler.T. Class 3:

CanWrite

Gets a value that indicates whether this ResolveHandler.T. can write elements.
The default value is true. (Inherited from ResolveHandler.T..)

RecursiveResolveHandler.T. Class 4:

Description

Gets a description that is used in Exception messages to display what was tried to resolve.
If Description is null, the Type of the instance that is actually resolved is displayed.
If the instance that is actually resolved is also null, the type of T is displayed. (Inherited from ResolveHandler.T..)

RecursiveResolveHandler.T. Class 5:

Resolver

Gets the RecursiveResolver.T. that is used to resolve instances of the specified type.

Methods

 

Name

Description

RecursiveResolveHandler.T. Class 6:

Equals

Determines whether the specified object is equal to the current object. (Inherited from Object.)

RecursiveResolveHandler.T. Class 7:

Finalize

Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection. (Inherited from Object.)

RecursiveResolveHandler.T. Class 8:

GetHashCode

Serves as the default hash function. (Inherited from Object.)

RecursiveResolveHandler.T. Class 9:

GetType

Gets the Type of the current instance. (Inherited from Object.)

RecursiveResolveHandler.T. Class 10:

MemberwiseClone

Creates a shallow copy of the current Object. (Inherited from Object.)

RecursiveResolveHandler.T. Class 11:

ReadElement

Reads the specified element from the current instance. (Overrides ResolveHandler.T..ReadElement(T, String).)

RecursiveResolveHandler.T. Class 12:

ReadElements

Reads the specified elements from the current instance. (Inherited from ResolveHandler.T..)

RecursiveResolveHandler.T. Class 13:

ToString

Returns a string that represents the current object. (Inherited from Object.)

RecursiveResolveHandler.T. Class 14:

WriteElement

Writes the specified value to the specified element of the current instance. (Overrides ResolveHandler.T..WriteElement(T, String, Object, Converter).)

RecursiveResolveHandler.T. Class 15:

WriteElements(T., Queue.String., T, Boolean)

Writes the specified value at the specified elements to the current instance.

RecursiveResolveHandler.T. Class 16:

WriteElements(T., Queue.String., Object, Converter, Boolean)

Writes the specified value at the specified elements to the current instance. (Inherited from ResolveHandler.T..)

Reference

TcHmiSrv.Core.Tools.Resolving.Handlers Namespace