Channel trigger sets refer to the actual variable from the scope configuration that can lead to the start of the trigger group based on a condition occurring. A trigger set can be regarded as a stand-alone trigger condition. Within a trigger group, trigger sets can also be linked to each other via logical operators. For variable selection, raw acquisitions from the data pool and interpreted variables from the channels are available. If raw acquisition is selected, it is possible to specify offset, scale factor and physical unit in the trigger set. For an interpreted acquisition, the data is taken from the selected channel.


Common
Combine | By selecting a logic operation these individual conditions can be placed in relation to one another. Note here that AND operations are handled before OR operations. |
Release | The release condition can be defined as follows: Rising Edge: Rising edge through x Falling Edge: Falling edge through x OnChangeEnds: End of a change |
Threshold | The numerical limit value that must be crossed |
Used Data | The interpreted acquisition or raw acquisition from the data pool (when an acquisition is selected, a new interpreter is created under the channel trigger set) |
Misc
Name | Each trigger set can have its own name |
Modify
Offset | Offset for a raw acquisition |
ScaleFactor | Scale factor for a raw acquisition |
Unit | Physical unit for a raw acquisition |
When a Trigger Set is triggered, the icon in the Solution Explorer changes from
to
. All trigger sets remain set until the entire trigger group has been triggered.