Adaptation of the acquisition data

private void SetAcquisitions(Channel channel)
{
    //AmsNetId and AmsPort need the TwinCAT.Ads.dll
    AdsAcquisition acq = new AdsAcquisition();
    acq.AmsNetIdExchange = "localhost";
    acq.TargetPort     = 851;
    acq.IsSymbolBased  = true;
    acq.SymbolName     = "Variables.aNormalDistribution";
    acq.DataType       = Scope2DataType.REAL64;
    acq.SampleTime     = (uint)(100 * TimeSpan.TicksPerMillisecond);
    acq.ArrayLength    = 2000;
    acq.Oversample     = 2000;
    channel.AddMember(acq);
}

The acquisition class of a channel describes the connection between the scope and the respective value of the machine controller. Therefore, for example, the name and size of a variable are expected at this point.

The acquisition object is hierarchically positioned below an AcquisitionInterpreter, which possesses further variable-independent information. Furthermore, the AcquisitionInterpreter is a member of a channel and, depending on the chart type, a channel may contain several AcquisitionInterpreters for the various axes. An acquisition can be appended directly to a channel as in the sample and the interpreter is automatically generated.