Bode Plot - Toolbar
The recording of a Bode Plot is started and stopped with the toolbar. The preset parameters for controlling the specified drive axis are used to follow the sought frequency profile.
| |
Risk of injury due to the drive axis starting up automatically In order to create the Bode Plot recording, the drive axis executes a motion sequence that is dependent upon the settings. At the start of the Bode Plot recording the drive axis starts up automatically in accordance with the set motion profile and can endanger people and material. During the Bode recording the drive axis remains integrated in the application context (e.g. enables, monitoring, etc.).
|
If the toolbar is not visible by default or has been closed, it can be reactivated under View > Toolbars > TwinCAT 3 Bode.

The following elements are available by default in the toolbar:
| Start Record: all plots connected to the selected Bode project start recording in parallel. The preset parameters are used to control the axes. |
| Stop Record: all plots connected to the selected Bode project abort the recording. The connected drive axes are reset to the original operation mode. |