Functionality: Light vs. full
If you do not have an Engineering license for TE1200 you can use the license-free version of Static Analysis (Static Analysis Light), which has some restrictions (see table below). The free Light version enables you to familiarize yourself with the basic handling of the product, for example, based on a heavily reduced set of functions.
Static Analysis Light vs. Static Analysis Full
An overview of the different features of the license-free and license-managed variants of Static Analysis is provided below.
Functional aspect | Static Analysis Light | Static Analysis Full |
License required | No, usable free of charge | Yes, TE1200 license required |
Save/export and load/import (rule) configuration | Not possible, coupled to PLC project properties | Possible (using the Load/Save buttons in the Settings) |
Execution is coupled to the compilation process | Yes, not configurable | Configurable (using the Perform static analysis automatically option in the Settings; Manual execution with the help of the command Command 'Run static analysis') |
Checking for unused objects (e.g. within a library project) | Not possible | Possible (with the help of the command Command 'Run static analysis [Check all objects]') |
Maximum number of reported errors | 500 (not configurable) (Further information on the significance of 500 as the maximum number of errors can be found in the Settings) | Configurable (using the setting Maximum number of errors in the Settings) |
Maximum number of reported warnings | Output of warnings not possible (see following line) | Configurable (using the setting Maximum number of warnings in the Settings) |
|
| |
7 coding rules
| More than 100 coding rules | |
Not available | Available | |
Not available | Available | |
Not available | Available | |
Not available | Available | |
Pragmas and attributes for temporary deactivation of rules | Yes, available in the Light scope:
| Yes, available in full scope:
|