AX2xxx Drive Tab - Online
"Online" Tab of AX2000-B200

"Online" Tab of AX2000-B900

The ASCII Objects of the AX2xxx drive are listed on this tab with current values (values are determined during tab opening). See also:Refresh
Refresh: To update the values shown in the listing, press this button.
Drive to Disk: Saves parameters with currently displayed values to disk. The file is stored in ASCII format and has the file extension *.axp.
Disk to Drive: Loads the parameter values of an previously stored *.axp file into the AX2xxx drive.
CLRFAULT: Calls the command for clearing of some defined drive errors (see AX2xxx manuals supplied on "Beckhoff Drive Technology" CD, also).
COLDSTART: Call the command for a initialising the drive (the Firmware) once again. Previously appeared errors are cleared then.
SAVE (EEPROM): Saves the downloaded parameters to the EEPROM of the drive. Therefore, the previous parameter changes will be active even after a coldstart of the drive.
Send String: Sends a single command (edited in the field right next to it) with a request for a parameter value to the drive. The feedback will be displayed in a message box after arrival.
Example:
If you enter the string FW, it would display e.g. the current drive Firmware version.


Example:
If you enter the string In3mode 2 the function of the third digital input (PSTP) will be changed.