ADS/AMS Settings at I/O-Devices
Devices with own ADS-AmsNetId (e.g. the Beckhoff AX2000 drive) have the following dialog for ADS/AMS settings.
At devices without own NetId or e.g. devices without Beckhoff Lightbus interface, only a part of the following items are present on the tab, but the existing ones have the same meaning.
"ADS/AMS" Tab

Enable String Communication
Enables the asynchronous communication at devices with Beckhoff Lightbus interface .
Port
Displays the ADS Port number of the current device.
Change
Makes a change of the Port number possible.
Max Timeout
Determines the allowed maximum response time for the ADS communication (in seconds).
Enable AMS / ADS
At devices with own NetId, this box must be checked.
NetId
Displays the ADS-AmsNetId of this device.
Remote Name
Displays the name of this device as it appears in the list of possible -> "AMS Remote Connections". This field can be edited by user.