FB_SimPosMotor
Position-controlled simulation motor.
This simulation motor travels automatically to the entered target position with a ramped velocity profile. The target position 'fTargetPosition' is transferred to 'bSet' with a rising edge. In addition to the present position, the current velocity and acceleration can be accessed at the outputs.
VAR_INPUT
VAR_INPUT
bRun : BOOL; (* Motor running *)
bSet : BOOL; (* Acitvates the move command *)
fTargetPosition : REAL; (* Target Position ~(EUnit:mm)*)
fMaxVelocity : REAL := 1000;(* Maximal Velocity ~(EUnit:m/s)*)
fMaxAcceleration : REAL := 100; (* Maximal Acceleration ~(EUnit:mm/s^2*)
END_VAR
bRun: Activates the simulation motor
bSet: Adoption of maximum velocity and target position on rising edge
fTargetPosition: Target position in mm
fMaxVelocity: Maximum velocity in mm/s
fMaxAcceleration: Max. acceleration in mm/s^2
VAR_OUTPUT
VAR_OUTPUT
fPosition : REAL := 0.0; (* Current position ~(EUnit:mm)*)
bPositionReached : BOOL := TRUE; (* Position reached *)
fVelocity : REAL := 0.0; (* Current velocity ~(EUnit:mm/s)*)
fAcceleration : REAL := 0.0; (* Current acceleration ~(EUnit:mm/s^2)*)
END_VAR
fPosition: Current position in mm
bPositionReached: TRUE when the pre-assigned position is reached
fVelocity: Current velocity in mm/s
fAcceleration: Current acceleration in mm/s^2
Requirements
Development | Target System | PLC Libraries to include |
|---|---|---|
TwinCAT v2.9.0 Build > 1020 | PC (i386) | TcSimManager.Lib (Standard.Lib; TcBase.Lib; TcSystem.Lib are included automatically) |