FB_CrestronGetClientConnectionState
This function block queries the connection status of a Crestron controller.
VAR_INPUT
sTargetIpAddr : STRING(15);
bExecute : BOOL;
tTimeout : TIME := T#5s;
sTargetIpAddr: IP address of the Crestron controller.
bExecute: A positive edge starts the block
tTimeout: Specifies the interval for awaiting a response.
VAR_OUTPUT
bConnectionState : BOOL;
bBusy : BOOL;
bError : BOOL;
udiErrorId : UDINT;
bConnectionState: The output is TRUE if a Crestron controller with the IP address entered at the input is connected to the Crestron Server.
bBusy: During the query procedure, the bBusy output is set to TRUE and remains TRUE until query has been completed. During this time no further commands can be activated via this block.
bError: The output is TRUE as soon as an error occurs during the execution of the command.
udiErrorId: Contains the error code that may occur during execution of the block. The value is 0 if no error has occurred.
Requirements
Development environment | Target system | Required libraries |
|---|---|---|
TwinCAT 2.11 R3/x64 | PC/CX | TcCrestron library from V1.0.0 |