Serial Bus Terminal
KL6xxx in 5-Byte Mode
Before a KL6xxx bus terminal can be used in 5-byte mode, it must be appropriately reconfigured. This can not be done through ComLib while running, but must be performed with the Beckhoff KS2000 configuration program. The terminal is then permanently set for 5-byte mode.
The serial bus terminal is now entered into the system under a bus coupler.

Then the input and output data are individually linked to the corresponding PLC variables (of types KL6inData5B and KL6outData5B).

The new configuration is activated, and the system is restarted.