MC_AxisPara
TYPE MC_AxisPara : (
(* PLCopen specific parameters *)
CommandedPosition := 1, (* lreal *)
SWLimitPos, (* lreal *)
SWLimitNeg, (* lreal *)
EnableLimitPos, (* bool *)
EnableLimitNeg, (* bool *)
EnablePosLagMonitoring, (* bool *)
MaxPositionLag, (* lreal *)
MaxVelocitySystem, (* lreal *)
MaxVelocityAppl, (* lreal *)
ActualVelocity, (* lreal *)
CommandedVelocity, (* lreal *)
MaxAccelerationSystem, (* lreal *)
MaxAccelerationAppl, (* lreal*)
MaxDecelerationSystem, (* lreal *)
MaxDecelerationAppl, (* lreal*)
MaxJerk, (* lreal *)
(* Beckhoff specific parameters *)
AxisId :=1000, (* lreal *)
AxisVeloManSlow, (* lreal *)
AxisVeloManFast, (* lreal *)
AxisVeloMax, (* lreal *)
AxisAcc, (* lreal *)
AxisDec, (* lreal *)
AxisJerk, (* lreal *)
AxisMaxVelocity, (* lreal *)
AxisRapidTraverseVelocity, (* lreal *)
AxisManualVelocityFast, (* lreal *)
AxisManualVelocitySlow, (* lreal *)
AxisCalibrationVelocityForward, (* lreal *)
AxisCalibrationVelocityBackward, (* lreal *)
AxisJogIncrementForward, (* lreal *)
AxisJogIncrementBackward, (* lreal *)
AxisEnMinSoftPosLimit, (* bool *)
AxisMinSoftPosLimit, (* lreal *)
AxisEnMaxSoftPosLimit, (* bool *)
AxisMaxSoftPosLimit, (* lreal *)
AxisEnPositionLagMonitoring, (* bool *)
AxisMaxPosLagValue, (* lreal *)
AxisMaxPosLagFilterTime, (* lreal *)
AxisEnPositionRangeMonitoring, (* bool *)
AxisPositionRangeWindow, (* lreal *)
AxisEnTargetPositionMonitoring, (* bool *)
AxisTargetPositionWindow, (* lreal *)
AxisTargetPositionMonitoringTime, (* lreal*)
AxisEnInTargetTimeout, (* bool *)
AxisInTargetTimeout, (* lreal *)
AxisEnMotionMonitoring, (* bool *)
AxisMotionMonitoringWindow, (* lreal *)
AxisMotionMonitoringTime, (* lreal *)
AxisDelayTimeVeloPosition, (* lreal *)
AxisEnLoopingDistance, (* bool *)
AxisLoopingDistance, (* lreal *)
AxisEnBacklashCompensation, (* bool *)
AxisBacklash, (* lreal *)
AxisEnDataPersistence, (* bool *)
AxisRefVeloOnRefOutput, (* lreal *)
AxisOverrideType, (* lreal *)
AxisEncoderScalingFactor, (* lreal *)
AxisEncoderOffset, (* lreal *)
AxisEncoderDirectionInverse, (* bool *)
AxisEncoderEncoderMask, (* dword *)
AxisEncoderModuloValue, (* lreal *)
AxisModuloToleranceWindow, (* lreal *)
AxisEnActPosCorrection, (* bool *)
AxisActPosCorrectionFilterTime, (* lreal *)
AxisUnitInterpretation, (* lreal - Bit 2 of this word is the modulo flag *)
(* Beckhoff specific axis status information - READ ONLY *)
AxisTargetPosition := 2000, (* lreal *)
AxisRemainingTimeToGo, (* lreal *)
AxisRemainingDistanceToGo (* lreal *)
);
END_TYPEIn this enum, the parameters for the blocks MC_ReadParameter, MC_ReadBoolParameter, MC_WriteParameter and MC_WriteBoolParameter are specified. If the data types do not coincide, or if an attempt is made to read a non-existing parameter, an error is generated.
Requirements
Development environment | Target system type | PLC libraries to be linked |
|---|---|---|
TwinCAT v2.8 | PC (i386) | TcMC.Lib |