E_LON_hvac_overid_t
Used by: SNVT_hvac_overid
TYPE E_LON_hvac_overid_t :
(
eLON_HVO_NUL := -1,
eLON_HVO_OFF := 0,
eLON_HVO_POSITION := 1,
eLON_HVO_FLOW_VALUE := 2,
eLON_HVO_FLOW_PERCENT := 3,
eLON_HVO_OPEN := 4,
eLON_HVO_CLOSE := 5,
eLON_HVO_MINIMUM := 6,
eLON_HVO_MAXIMUM := 7,
eLON_HVO_UNUSED8 := 8,
eLON_HVO_UNUSED9 := 9,
eLON_HVO_UNUSED10 := 10,
eLON_HVO_UNUSED11 := 11,
eLON_HVO_UNUSED12 := 12,
eLON_HVO_UNUSED13 := 13,
eLON_HVO_UNUSED14 := 14,
eLON_HVO_UNUSED15 := 15,
eLON_HVO_UNUSED16 := 16,
eLON_HVO_POSITION_1 := 17,
eLON_HVO_FLOW_VALUE_1 := 18,
eLON_HVO_FLOW_PERCENT_1 := 19,
eLON_HVO_OPEN_1 := 20,
eLON_HVO_CLOSE_1 := 21,
eLON_HVO_MINIMUM_1 := 22,
eLON_HVO_MAXIMUM_1 := 23,
eLON_HVO_UNUSED24 := 24,
eLON_HVO_UNUSED25 := 25,
eLON_HVO_UNUSED26 := 26,
eLON_HVO_UNUSED27 := 27,
eLON_HVO_UNUSED28 := 28,
eLON_HVO_UNUSED29 := 29,
eLON_HVO_UNUSED30 := 30,
eLON_HVO_UNUSED31 := 31,
eLON_HVO_UNUSED32 := 32,
eLON_HVO_POSITION_2 := 33,
eLON_HVO_FLOW_VALUE_2 := 34,
eLON_HVO_FLOW_PERCENT_2 := 35,
eLON_HVO_OPEN_2 := 36,
eLON_HVO_CLOSE_2 := 37,
eLON_HVO_MINIMUM_2 := 38,
eLON_HVO_MAXIMUM_2 := 39,
eLON_HVO_UNUSED40 := 40,
eLON_HVO_UNUSED41 := 41,
eLON_HVO_UNUSED42 := 42,
eLON_HVO_UNUSED43 := 43,
eLON_HVO_UNUSED44 := 44,
eLON_HVO_UNUSED45 := 45,
eLON_HVO_UNUSED46 := 46,
eLON_HVO_UNUSED47 := 47,
eLON_HVO_UNUSED48 := 48
)
END_TYPE
eLON_HVO_NUL: Invalid Value
eLON_HVO_OFF: Not overridden
eLON_HVO_POSITION:
eLON_HVO_FLOW_VALUE: Override flow in liters/sec - use flow field
eLON_HVO_FLOW_PERCENT: Override flow percentage - use percent field
eLON_HVO_OPEN: Override to position = 100%
eLON_HVO_CLOSE: Override to position = 0%
eLON_HVO_MINIMUM: Override to configured minimum
eLON_HVO_MAXIMUM: Override to configured maximum
eLON_HVO_UNUSED8:
eLON_HVO_UNUSED9:
eLON_HVO_UNUSED10:
eLON_HVO_UNUSED11:
eLON_HVO_UNUSED12:
eLON_HVO_UNUSED13:
eLON_HVO_UNUSED14:
eLON_HVO_UNUSED15:
eLON_HVO_UNUSED16:
eLON_HVO_POSITION_1:
eLON_HVO_FLOW_VALUE_1: Override flow in liters/sec - use flow field
eLON_HVO_FLOW_PERCENT_1: Override flow percentage - use percent field
eLON_HVO_OPEN_1: Override to position = 100%
eLON_HVO_CLOSE_1: Override to position = 0%
eLON_HVO_MINIMUM_1: Override to configured minimum
eLON_HVO_MAXIMUM_1: Override to configured maximum
eLON_HVO_UNUSED24:
eLON_HVO_UNUSED25:
eLON_HVO_UNUSED26:
eLON_HVO_UNUSED27:
eLON_HVO_UNUSED28:
eLON_HVO_UNUSED29:
eLON_HVO_UNUSED30:
eLON_HVO_UNUSED31:
eLON_HVO_UNUSED32:
eLON_HVO_POSITION_2:
eLON_HVO_FLOW_VALUE_2: Override flow in liters/sec - use flow field
eLON_HVO_FLOW_PERCENT_2: Override flow percentage - use percent field
eLON_HVO_OPEN_2: Override to position = 100%
eLON_HVO_CLOSE_2: Override to position = 0%
eLON_HVO_MINIMUM_2: Override to configured minimum
eLON_HVO_MAXIMUM_2: Override to configured maximum
eLON_HVO_UNUSED40:
eLON_HVO_UNUSED41:
eLON_HVO_UNUSED42:
eLON_HVO_UNUSED43:
eLON_HVO_UNUSED44:
eLON_HVO_UNUSED45:
eLON_HVO_UNUSED46:
eLON_HVO_UNUSED47:
eLON_HVO_UNUSED48: