M_AcknowledgeWarning
This method acknowledges a warning in the Admin-Tags. Warning[].Trigger is set to FALSE and the value from Admin.PlcDateTime is entered in Warning[].AckDateTime. The method returns TRUE if the warning was found and acknowledged successfully. The warning remains in the Warning array until it is pushed out of the array by the next warning.
![]() | So that a valid timestamp can be entered, the PML_AdminTime function block should be called cyclically in the program. |
Syntax
METHOD M_AcknowledgeWarning : BOOL
VAR_IN_OUT
stAdmin : ST_PMLa;
END_VAR
VAR_INPUT
stWarning : ST_PMLEvent;
END_VAR
Example call:
WarningAcknowledged := fbAdminAlarm.M_AcknowledgeWarning(stAdmin := PackTags.Admin, stWarning := Warning);Requirements
Development Environment | Target platform | PLC library to include |
|---|---|---|
From TwinCAT
| PC (i386) | From Tc3_PackML_ V3 1.0.3 |
