M_AcknowledgeAlarm
This method acknowledges an alarm in the Admin-Tags. Alarm[].Trigger is set to FALSE and the value from Admin.PlcDateTime is entered in Alarm[].AckDateTime. The method returns TRUE if the alarm was found and acknowledged successfully. Acknowledging the alarm does not delete it. The alarm remains in the Alarm array until an M_ClearAlarm has been called, then it is moved to the AlarmHistory array. If the AlarmHistory array is already full of entries, the oldest entry is deleted as a result.
|  | So that a valid timestamp can be entered, the PML_AdminTime function block should be called cyclically in the program. | 
Syntax
METHOD M_AcknowledgeAlarm : BOOL
VAR_IN_OUT
  stAdmin          : ST_PMLa;
END_VAR
VAR_INPUT
  stAlarm          : ST_PMLEvent;
END_VAR
Example call:
AlarmAcknowledged := fbAdminAlarm.M_AcknowledgeAlarm(stAdmin := PackTags.Admin, stAlarm := Alarm);
Requirements
| Development Environment | Target platform | PLC library to include | 
|---|---|---|
| From TwinCAT 
 | PC (i386) | From Tc3_PackML_ V3 1.0.3 |