M_ClearStopReason

This method deletes a StopReason from the Admin-Tags. StopReason[].Trigger is set to FALSE. The method returns TRUE if the StopReason was deleted successfully. The StopReason remains in the StopReason array until it is pushed out of the array by the next StopReason.

M_ClearStopReason 1:

So that a valid timestamp can be entered, the function block PML_AdminTime should be called cyclically in the program.

Syntax

METHOD M_ClearAlarm : BOOL
VAR_IN_OUT
  stAdmin          : ST_PMLa;
END_VAR
VAR_INPUT
  stStopReason     : ST_Alarm;
END_VAR

Sample call:

StopReasonCleared := fbAdminAlarm.M_ClearStopReason(stAdmin := PackTags.Admin, stStopReason := StopReason);

Requirements

Development environment

Target system type

PLC libraries to include

TwinCAT v3.1 Build 4018 and higher

PC (i386)

Tc3_PackML_V2