M_SetStopReason
This method inserts a StopReason in the Admin-Tags. StopReason[].Trigger is set to TRUE and the value from Admin.PlcDateTime is entered in StopReason[].DateTime. The other values are taken from the transferred StopReason structure. The method returns TRUE if the StopReason was entered successfully. If the StopReason array is already full of entries, the oldest entry is deleted as a result.
![]() | So that a valid timestamp can be entered, the function block PML_AdminTime should be called cyclically in the program. |
Syntax
METHOD M_SetStopReason : BOOL
VAR_IN_OUT
stAdmin : ST_PMLa;
END_VAR
VAR_INPUT
stStopReason : ST_Alarm;
END_VAR
Sample call:
StopReasonInserted := fbAdminAlarm.M_SetStopReason (stAdmin := PackTags.Admin, stStopReason := StopReason);
Requirements
Development environment | Target system type | PLC library to include |
|---|---|---|
TwinCAT v3.1 Build 4018 and higher | PC (i386) | Tc3_PackML_V2 |