M_SetAlarm

This method inserts an alarm in the Admin-Tags. Alarm[].Trigger is set to TRUE and the value from Admin.PlcDateTime is entered in Alarm[].DateTime. The other values are taken from the transferred alarm structure. The method returns TRUE if the alarm was entered successfully

M_SetAlarm 1:

So that a valid timestamp can be entered, the function block PML_AdminTime should be called cyclically in the program.

Syntax

METHOD M_SetAlarm : BOOL
VAR_IN_OUT
  stAdmin          : ST_PMLa;
END_VAR
VAR_INPUT
  stAlarm          : ST_Alarm;
END_VAR

Sample call:

AlarmInserted := fbAdminAlarm.M_SetAlarm(stAdmin := PackTags.Admin, stAlarm := Alarm);

Requirements

Development environment

Target system type

PLC library to include

TwinCAT v3.1 Build 4018 and higher

PC (i386)

Tc3_PackML_V2