Tag Details

The following section provides an overview of the tags. Command, state and administration PackTags are listed in the following tables.

Command structure PMLc

 

 

 

 

 

Tag Name

Data Type

PMLc

 

 

 

 

PMLc

ST_PMLc

 

UnitMode

 

 

 

PMLc.UnitMode

DINT

 

UnitModeChangeRequest

 

 

 

PMLc.UnitModeChangeRequest

BOOL

 

MachSpeed

 

 

 

PMLc.MachSpeed

REAL

 

MaterialInterlock

 

 

 

PMLc.MaterialInterlock

DINT

 

CntrlCmd

 

 

 

PMLc.CntrlCmd

DINT

 

CmdChangeRequest

 

 

 

PMLc.CmdChangeRequest

BOOL

 

RemoteInterface[#]

 

 

 

PMLc.RemoteInterface[#]

ST_Interface

 

 

Number

 

 

PMLc.RemoteInterface[#].Number

DINT

 

 

ControlCmdNumber

 

 

PMLc.RemoteInterface[#].ControlCmdNumber

DINT

 

 

CmdValue

 

 

PMLc.RemoteInterface[#].CmdValue

DINT

 

 

Parameter[#]

 

 

PMLc.RemoteInterface[#].Parameter[#]

ST_Descriptor

 

 

 

Id

 

PMLc.RemoteInterface[#].Parameter[#].Id

DINT

 

 

 

Name

 

PMLc.RemoteInterface[#].Parameter[#].Name

STRING

 

 

 

Unit

 

PMLc.RemoteInterface[#].Parameter[#].Unit

STRING(5)

 

 

 

Value

 

PMLc.RemoteInterface[#].Parameter[#].Value

REAL

 

Parameter[#]

 

 

 

PMLc.Parameter[#]

ST_Descriptor

 

 

Id

 

 

PMLc..Parameter[#].Id

DINT

 

 

Name

 

 

PMLc..Parameter[#].Name

STRING

 

 

Unit

 

 

PMLc..Parameter[#].Unit

STRING(5)

 

 

Value

 

 

PMLc..Parameter[#].Value

REAL

 

Product[#]

 

 

 

PMLc.Product[#]

ST_Product

 

 

ProductId

 

 

PMLc.Product[#]

DINT

 

 

ProcessVariables[#]

 

 

PMLc.Product[#].ProcessVariables[#]

ST_Descriptor

 

 

 

Id

 

PMLc.Product[#].ProcessVariables[#].Id

DINT

 

 

 

Name

 

PMLc.Product[#].ProcessVariables[#].Name

STRING

 

 

 

Unit

 

PMLc.Product[#].ProcessVariables[#].Unit

STRING(5)

 

 

 

Value

 

PMLc.Product[#].ProcessVariables[#].Value

REAL

 

 

Ingredients[#]

 

 

PMLc.Product[#].Ingredients[#]

ST_Ingredient

 

 

 

IngredientId

 

PMLc.Product[#].Ingredients[#].IngredientId

DINT

 

 

 

Parameter[#]

 

PMLc.Product[#].Ingredients[#].Parameter[#]

ST_Descriptor

 

 

 

 

Id

PMLc.Product[#].Ingredients[#].Parameter[#].Id

DINT

 

 

 

 

Name

PMLc.Product[#].Ingredients[#].Parameter[#].Name

STRING

 

 

 

 

Unit

PMLc.Product[#].Ingredients[#].Parameter[#].Unit

STRING(5)

 

 

 

 

Value

PMLc.Product[#].Ingredients[#].Parameter[#].Value

REAL

State structure PMLs

 

 

 

 

 

Tag Name

Data Type

PMLs

 

 

 

 

PMLs

ST_PMLs

 

UnitModeCurrent

 

 

 

PMLs.UnitModeCurrent

DINT

 

UnitModeRequested

 

 

 

PMLs.UnitModerequested

DINT

 

UnitModeChangeInProcess

 

 

 

PMLs.UnitModeChangeInProcess

BOOL

 

StateCurrent

 

 

 

PMLs.StateCurrent

DINT

 

StateRequested

 

 

 

PMLs.StateRequested

DINT

 

StateChangeInProcess

 

 

 

PMLs.StateChangeInProcess

BOOL

 

MachineSpeed

 

 

 

PMLs.MachineSpeed

REAL

 

CurMachineSpeed

 

 

 

PMLs.CurMachineSpeed

REAL

 

MaterialInterlock

 

 

 

PMLs.MaterialInterlock

DINT

 

EquipmentInterlock

 

 

 

PMLs.EquipmentInterlock

ST_Equipment

 

 

Blocked

 

 

PMLs.EquipmentInterlock.Blocked

BOOL

 

 

Starved

 

 

PMLs.EquipmentInterlock.Starved

BOOL

 

RemoteInterface[#]

 

 

 

PMLs.RemoteInterface[#]

ST_Interface

 

 

Number

 

 

PMLs.RemoteInterface[#].Number

DINT

 

 

ControlCmdNumber

 

 

PMLs.RemoteInterface[#].ControlCmdNumber

DINT

 

 

CmdValue

 

 

PMLs.RemoteInterface[#].CmdValue

DINT

 

 

Parameter[#]

 

 

PMLs.RemoteInterface[#].Parameter[#]

ST_Descriptor

 

 

 

Id

 

PMLs.RemoteInterface[#].Parameter[#].Id

DINT

 

 

 

Name

 

PMLs.RemoteInterface[#].Parameter[#].Name

STRING

 

 

 

Unit

 

PMLs.RemoteInterface[#].Parameter[#].Unit

STRING(5)

 

 

 

Value

 

PMLs.RemoteInterface[#].Parameter[#].Value

REAL

 

Parameter[#]

 

 

 

PMLs.Parameter[#]

ST_Descriptor

 

 

Id

 

 

PMLs..Parameter[#].Id

DINT

 

 

Name

 

 

PMLs..Parameter[#].Name

STRING

 

 

Unit

 

 

PMLs..Parameter[#].Unit

STRING(5)

 

 

Value

 

 

PMLs..Parameter[#].Value

REAL

 

Product[#]

 

 

 

PMLc.Product[#]

ST_Product

 

 

ProductId

 

 

PMLc.Product[#].ProductId

DINT

 

 

ProcessVariables[#]

 

 

PMLc.Product[#].ProcessVariables[#]

ST_Descriptor

 

 

 

Id

 

PMLc.Product[#].ProcessVariables[#].Id

DINT

 

 

 

Name

 

PMLc.Product[#].ProcessVariables[#].Name

STRING

 

 

 

Unit

 

PMLc.Product[#].ProcessVariables[#].Unit

STRING(5)

 

 

 

Value

 

PMLc.Product[#].ProcessVariables[#].Value

REAL

 

 

Ingredients[#]

 

 

PMLc.Product[#].Ingredients[#]

ST_Ingredient

 

 

 

IngredientId

 

PMLc.Product[#].Ingredients[#].IngredientId

DINT

 

 

 

Parameter[#]

 

PMLc.Product[#].Ingredients[#].Parameter[#]

ST_Descriptor

 

 

 

 

Id

PMLc.Product[#].Ingredients[#].Parameter[#].Id

DINT

 

 

 

 

Name

PMLc.Product[#].Ingredients[#].Parameter[#].Name

STRING

 

 

 

 

Unit

PMLc.Product[#].Ingredients[#].Parameter[#].Unit

STRING(5)

 

 

 

 

Value

PMLc.Product[#].Ingredients[#].Parameter[#].Value

REAL

PMLa administration structure

 

 

 

 

 

Tag Name

Data Type

PMLa

 

 

 

 

Admin

ST_PMLa

 

Parameter[#]

 

 

 

PMLa.Parameter[#]

ST_Descriptor

 

 

Id

 

 

PMLa..Parameter[#].Id

DINT

 

 

Name

 

 

PMLa..Parameter[#].Name

STRING

 

 

Unit

 

 

PMLa..Parameter[#].Unit

STRING(5)

 

 

Value

 

 

PMLa..Parameter[#].Value

REAL

 

Alarm[#]

 

 

 

PMLa.Alarm[#]

ST_Alarm

 

 

Trigger

 

 

PMLa.Alarm[#].Trigger

BOOL

 

 

Id

 

 

PMLa.Alarm[#].Id

DINT

 

 

Value

 

 

PMLa.Alarm[#].Value

DINT

 

 

Message

 

 

PMLa.Alarm[#].Message

STRING

 

 

Category

 

 

PMLa.Alarm[#].Category

DINT

 

 

DateTime

 

 

PMLa.Alarm[#].DateTime

ARRAY [0..6] OF DINT

 

 

 

Year

 

PMLa.Alarm[#].DateTime[0]

DINT

 

 

 

Month

 

PMLa.Alarm[#].DateTime[1]

DINT

 

 

 

Day

 

PMLa.Alarm[#].DateTime.[2]

DINT

 

 

 

Hour

 

PMLa.Alarm[#].DateTime[3]

DINT

 

 

 

Minute

 

PMLa.Alarm[#].DateTime[4]

DINT

 

 

 

Second

 

PMLa.Alarm[#].DateTime[5]

DINT

 

 

 

mSec

 

PMLa.Alarm[#].DateTime[6]

DINT

 

 

AckDateTime

 

 

PMLa.Alarm[#].AckDateTime

ARRAY [0..6] OF DINT

 

 

 

Year

 

PMLa.Alarm[#].AckDateTime[0]

DINT

 

 

 

Month

 

PMLa.Alarm[#].AckDateTime[1]

DINT

 

 

 

Day

 

PMLa.Alarm[#].AckDateTime[2]

DINT

 

 

 

Hour

 

PMLa.Alarm[#].AckDateTime[3]

DINT

 

 

 

Minute

 

PMLa.Alarm[#].AckDateTime[4]

DINT

 

 

 

Second

 

PMLa.Alarm[#].AckDateTime[5]

DINT

 

 

 

mSec

 

PMLa.Alarm[#].AckDateTime[6]

DINT

 

AlarmExtent

 

 

 

PMLa.AlarmExtent

DINT

 

AlarmHistory[#]

 

 

 

PMLa.AlarmHistory[#]

ST_Alarm

 

 

Trigger

 

 

PMLa.AlarmHistory[#].Trigger

BOOL

 

 

Id

 

 

PMLa.AlarmHistory[#].Id

DINT

 

 

Value

 

 

PMLa.AlarmHistory[#].Value

DINT

 

 

Message

 

 

PMLa.AlarmHistory[#].Message

STRING

 

 

Category

 

 

PMLa.AlarmHistory[#].Category

DINT

 

 

DateTime

 

 

PMLa.AlarmHistory[#].DateTime

ARRAY [0..6] OF DINT

 

 

 

Year

 

PMLa.AlarmHistory[#].DateTime[0]

DINT

 

 

 

Month

 

PMLa.AlarmHistory[#].DateTime[1]

DINT

 

 

 

Day

 

PMLa.AlarmHistory[#].DateTime[2]

DINT

 

 

 

Hour

 

PMLa.AlarmHistory[#].DateTime[3]

DINT

 

 

 

Minute

 

PMLa.AlarmHistory[#].DateTime[4]

DINT

 

 

 

Second

 

PMLa.AlarmHistory[#].DateTime[5]

DINT

 

 

 

mSec

 

PMLa.AlarmHistory[#].DateTime[6]

DINT

 

 

AckDateTime

 

 

PMLa.AlarmHistory[#].AckDateTime

ARRAY [0..6] OF DINT

 

 

 

Year

 

PMLa.AlarmHistory[#].AckDateTime[0]

DINT

 

 

 

Month

 

PMLa.AlarmHistory[#].AckDateTime[1]

DINT

 

 

 

Day

 

PMLa.AlarmHistory[#].AckDateTime[2]

DINT

 

 

 

Hour

 

PMLa.AlarmHistory[#].AckDateTime[3]

DINT

 

 

 

Minute

 

PMLa.AlarmHistory[#].AckDateTime[4]

DINT

 

 

 

Second

 

PMLa.AlarmHistory[#].AckDateTime[5]

DINT

 

 

 

mSec

 

PMLa.AlarmHistory[#].AckDateTime[6]

DINT

 

AlarmHistoryExtent

 

 

 

PMLa.AlarmHistoryExtent

DINT

 

StopReason[#]

 

 

 

PMLa.StopReason[#]

ST_Alarm

 

 

Trigger

 

 

PMLa.StopReason[#].Trigger

BOOL

 

 

Id

 

 

PMLa.StopReason[#].Id

DINT

 

 

Value

 

 

PMLa.StopReason[#].Value

DINT

 

 

Message

 

 

PMLa.StopReason[#].Message

STRING

 

 

Category

 

 

PMLa.StopReason[#].Category

DINT

 

 

DateTime

 

 

PMLa.StopReason[#].DateTime

ARRAY [0..6] OF DINT

 

 

 

Year

 

PMLa.StopReason[#].DateTime[0]

DINT

 

 

 

Month

 

PMLa.StopReason[#].DateTime[1]

DINT

 

 

 

Day

 

PMLa.StopReason[#].DateTime[2]

DINT

 

 

 

Hour

 

PMLa.StopReason[#].DateTime[3]

DINT

 

 

 

Minute

 

PMLa.StopReason[#].DateTime[4]

DINT

 

 

 

Second

 

PMLa.StopReason[#].DateTime[5]

DINT

 

 

 

mSec

 

PMLa.StopReason[#].DateTime[6]

DINT

 

 

AckDateTime

 

 

PMLa.StopReason[#].AckDateTime

ARRAY [0..6] OF DINT

 

 

 

Year

 

PMLa.StopReason[#].AckDateTime[0]

DINT

 

 

 

Month

 

PMLa.StopReason[#].AckDateTime[1]

DINT

 

 

 

Day

 

PMLa.StopReason[#].AckDateTime[2]

DINT

 

 

 

Hour

 

PMLa.StopReason[#].AckDateTime[3]

DINT

 

 

 

Minute

 

PMLa.StopReason[#].AckDateTime[4]

DINT

 

 

 

Second

 

PMLa.StopReason[#].AckDateTime[5]

DINT

 

 

 

mSec

 

PMLa.StopReason[#].AckDateTime[6]

DINT

 

StopReasonExtent

 

 

 

PMLa.StopReasonExtent

DINT

 

Warning[#]

 

 

 

PMLa.Warning[#]

ST_Alarm

 

 

Trigger

 

 

PMLa.Warning [#].Trigger

BOOL

 

 

Id

 

 

PMLa.Warning[#].Id

DINT

 

 

Value

 

 

PMLa.Warning[#].Value

DINT

 

 

Message

 

 

PMLa.Warning[#].Message

STRING

 

 

Category

 

 

PMLa.Warning[#].Category

DINT

 

 

DateTime

 

 

PMLa.Warning[#].DateTime

ARRAY [0..6] OF DINT

 

 

 

Year

 

PMLa.Warning[#].DateTime[0]

DINT

 

 

 

Month

 

PMLa.Warning[#].DateTime[1]

DINT

 

 

 

Day

 

PMLa.Warning[#].DateTime[2]

DINT

 

 

 

Hour

 

PMLa.Warning[#].DateTime[3]

DINT

 

 

 

Minute

 

PMLa.Warning[#].DateTime[4]

DINT

 

 

 

Second

 

PMLa.Warning[#].DateTime[5]

DINT

 

 

 

mSec

 

PMLa.Warning[#].DateTime[6]

DINT

 

 

AckDateTime

 

 

PMLa.Warning[#].AckDateTime

ARRAY [0..6] OF DINT

 

 

 

Year

 

PMLa.Warning[#].AckDateTime[0]

DINT

 

 

 

Month

 

PMLa.Warning[#].AckDateTime[1]

DINT

 

 

 

Day

 

PMLa.Warning[#].AckDateTime[2]

DINT

 

 

 

Hour

 

PMLa.Warning[#].AckDateTime[3]

DINT

 

 

 

Minute

 

PMLa.Warning[#].AckDateTime[4]

DINT

 

 

 

Second

 

PMLa.Warning[#].AckDateTime[5]

DINT

 

 

 

mSec

 

PMLa.Warning[#].AckDateTime[6]

DINT

 

WarningExtent

 

 

 

PMLa.WarningExtent

DINT

 

ModeCurrentTime[#]

 

 

 

PMLa.ModeCurrentTime[#]

DINT

 

ModeCummulativeTime[#]

 

 

 

PMLa.ModeCummulativeTime[#]

DINT

 

StateCurrentTime[#,#]

 

 

 

PMLa.StateCurrentTime[#,#]

DINT

 

StateCummulativeTime[#,#]

 

 

 

PMLa.StateCummulativeTime[#,#]

DINT

 

ProdConsumedCount[#]

 

 

 

PMLa.ProdConsumedCount[#]

 

 

 

Id

 

 

PMLa.ProdConsumedCount[#].Id

DINT

 

 

Name

 

 

PMLa.ProdConsumedCount[#].Name

STRING

 

 

Unit

 

 

PMLa.ProdConsumedCount[#].Unit

STRING(5)

 

 

Count

 

 

PMLa.ProdConsumedCount[#].Count

DINT

 

 

AccCount

 

 

PMLa.ProdConsumedCount[#].AccCount

DINT

 

ProdProcessedCount[#]

 

 

 

PMLa.ProdProcessedCount[#]

 

 

 

Id

 

 

PMLa.ProdProcessedCount[#].Id

DINT

 

 

Name

 

 

PMLa.ProdProcessedCount[#].Name

STRING

 

 

Unit

 

 

PMLa.ProdProcessedCount[#].Unit

STRING(5)

 

 

Count

 

 

PMLa.ProdProcessedCount[#].Count

DINT

 

 

AccCount

 

 

PMLa.ProdProcessedCount[#].AccCount

DINT

 

ProdDefectiveCount[#]

 

 

 

PMLa.ProdDefectiveCount[#]

 

 

 

Id

 

 

PMLa.ProdDefectiveCount[#].Id

DINT

 

 

Name

 

 

PMLa.ProdDefectiveCount[#].Name

STRING

 

 

Unit

 

 

PMLa.ProdDefectiveCount[#].Unit

STRING(5)

 

 

Count

 

 

PMLa.ProdDefectiveCount[#].Count

DINT

 

 

AccCount

 

 

PMLa.ProdDefectiveCount[#].AccCount

DINT

 

AccTimeSinceReset

 

 

 

PMLa.AccTimeSinceReset

DINT

 

MachDesignSpeed

 

 

 

PMLa.MachDesignSpeed

REAL

 

StatesDisabled

 

 

 

PMLa.StatesDisabled

DINT

 

PlcDateTime

 

 

 

PMLa.PlcDateTime

ARRAY [0..6] OF DINT

 

 

Year

 

 

PMLa.PlcDateTime[0]

DINT

 

 

Month

 

 

PMLa.PlcDateTime[1]

DINT

 

 

Day

 

 

PMLa.PlcDateTime[2]

DINT

 

 

Hour

 

 

PMLa.PlcDateTime[3]

DINT

 

 

Minute

 

 

PMLa.PlcDateTime[4]

DINT

 

 

Second

 

 

PMLa.PlcDateTime[5]

DINT

 

 

mSec

 

 

PMLa.PlcDateTime[6]

DINT