FW_ObjMgr_CreateAndInitInstance

FW_ObjMgr_CreateAndInitInstance 1:

This function generates an instance of the class specified by means of Class-ID and at the same time returns an interface pointer to this object. In addition the object name and state into which the object is to be put can be specified.

FW_ObjMgr_CreateAndInitInstance 2: Return value

FW_ObjMgr_CreateAndInitInstance : HRESULT;

Name

Type

Description

FW_ObjMgr_CreateAndInitInstance

HRESULT

Returns S_OK if the function call was successful.

FW_ObjMgr_CreateAndInitInstance 3: Inputs

VAR_INPUT
    clsId     : CLSID;
    iid       : IID;
    pipUnk    : POINTER TO ITcUnknown;
    objId     : UDINT;
    parentId  : UDINT;
    name      : REFERENCE TO STRING;
    state     : UDINT;
    pInitData : POINTER TO TComInitDataHdr;
END_VAR

Name

Type

Description

clsId

CLSID

Specifies the class from which an object should be created.

iid

IID

Specifies the interface ID to which an interface pointer should be referenced.

pipUnk

POINTER TO ITcUnknown

Returns the interface pointer to the created object.

objId

UDINT

Specifies the object ID for the newly created object. If the global constant OTCID_CreateNewId is entered here a new object ID is generated internally.

parentId

UDINT

Object ID of the parent object (optional)
Here the object ID of the PLC instance can be specified from which this function is called. (TwinCAT_SystemInfoVarList._AppInfo.ObjId).

name

REFERENCE TO STRING

Specifies the object name which should be assigned for the newly created object.

State

UDINT

Specifies the state into which the newly created object should be put. Typically Operational (TCOM_STATE.TCOM_STATE_OP) is specified.

pInitData

POINTER TO TComInitDataHdr

Pointer to initialization parameter (optional) (for internal use only)

FW_ObjMgr_CreateAndInitInstance 4:

Necessary deletion of an object

A generated object must be explicitly deleted again. There is no Garbage-Collector as in .Net. We recommend to use FW_ObjMgr_DeleteInstance, in order to delete the generated instance at the latest in the destructor of the object which created the instance.

Requirements

TwinCAT Version

Hardware

Libraries to be integrated

TwinCAT 3.1, Build 4020

x86, x64, ARM

Tc3_Module