Tc3JsonXmlSampleXmlDomWriter
This sample illustrates how an XML document can be created programmatically based on DOM. The function block FB_XmlDomParser is used as a basis.
Declaration range
PROGRAM MAIN
VAR
fbXml : FB_XmlDomParser;
objRoot : SXmlNode;
objMachines : SXmlNode;
objMachine : SXmlNode;
objControllers : SXmlNode;
objController : SXmlNode;
objAttribute : SXmlAttribute;
sXmlString : STRING(1000);
bCreate : BOOL := FALSE;
bSave : BOOL := TRUE;
nLength : UDINT;
newAttr : SXmlAttribute;
END_VARImplementation range
The implementation section shows various options for creating an XML document.
IF bCreate THEN
(* Create an empty XML document *)
objRoot := fbXml.GetDocumentNode();
(* Create a new XML node 'Machines' and add to the empty document *)
objMachines := fbXml.AppendNode(objRoot, 'Machines');
(* Create a new XML node 'Machine' and add an attribute to this node. Append node to 'Machines' *)
objMachine := fbXml.AppendNode(objMachines, 'Machine');
objAttribute := fbXml.AppendAttribute(objMachine, 'Name', 'Wilde Nelli');
(* Create a new XML node 'Controllers' and add to the 'Machine' node *)
objControllers := fbXml.AppendNode(objMachine, 'Controllers');
(* Create a new XML node 'Controller' and add some attributes. Append node to 'Controllers'. *)
objController := fbXml.AppendChild(objControllers, 'Controller', 'CX5120', FALSE);
objAttribute := fbXml.AppendAttribute(objController, 'Type', 'EPC');
objAttribute := fbXml.AppendAttribute(objController, 'OS', 'Windows Embedded Compact 7');
(* Create a new XML node 'Controller' and add some attributes. Append node to 'Controllers'. *)
objController := fbXml.AppendChild(objControllers, 'Controller', 'CX2040', FALSE);
objAttribute := fbXml.AppendAttribute(objController, 'Type', 'EPC');
objAttribute := fbXml.AppendAttribute(objController, 'OS', 'Windows Embedded Standard 7');
(* Create a new XML node 'Controller' and add some attributes. Append node to 'Controllers'. *)
objController := fbXml.AppendChild(objControllers, 'Controller', 'C6015', FALSE);
objAttribute := fbXml.AppendAttribute(objController, 'Type', 'IPC');
objAttribute := fbXml.AppendAttribute(objController, 'OS', 'Windows 10 IoT Enterprise');
(* Create a new XML node 'Machine' and add an attribute to this node. Append node to 'Machines' *)
objMachine := fbXml.AppendNode(objMachines, 'Machine');
objAttribute := fbXml.AppendAttribute(objMachine, 'Name', 'Stanze Oscar');
(* Create a new XML node 'Controllers' and add to the 'Machine' node *)
objControllers := fbXml.AppendNode(objMachine, 'Controllers');
(* Create a new XML node 'Controller' and add some attributes. Append node to 'Controllers'. *)
objController := fbXml.AppendChild(objControllers, 'Controller', 'C6017', FALSE);
objAttribute := fbXml.AppendAttribute(objController, 'Type', 'IPC');
objAttribute := fbXml.AppendAttribute(objController, 'OS', 'Windows 10 IoT Enterprise');
newAttr := fbXml.InsertAttribute(objController, objAttribute, 'AddAttribute');
fbXml.SetAttribute(newAttr, 'Hola');
(* Retrieve XML document and store in a variable of data type STRING(1000) *)
nLength := fbXml.CopyDocument(sXmlString, SIZEOF(sXmlString));
bCreate := FALSE;
END_IF