Tc3JsonXmlSampleXmlDomReader
This sample illustrates how an XML document can be processed programmatically based on DOM. The function block FB_XmlDomParser is used as a basis.
Declaration range
PROGRAM MAIN
VAR
fbXml : FB_XmlDomParser;
xmlDoc : SXmlNode;
xmlMachines : SXmlNode;
xmlMachine1 : SXmlNode;
xmlMachine2 : SXmlNode;
xmlIterator : SXmlIterator;
xmlMachineNode : SXmlNode;
xmlMachineNodeValue : STRING;
xmlMachineAttributeRef : SXmlAttribute;
xmlMachine1Attribute : SXmlAttribute;
xmlMachine2Attribute : SXmlAttribute;
sMachine1Name : STRING;
sMachine2Name : STRING;
nMachineAttribute : DINT;
nMachine1Attribute : DINT;
nMachine2Attribute : DINT;
sMessageToParse : STRING(255) := '<Machines><Machine Type="1" Test="3">Wilde Nelli</Machine><Machine Type="2">Huber8</Machine></Machines>';
END_VARImplementation range
The implementation section shows various options for parsing an XML document.
(* Load XML content *)
xmlDoc := fbXml.ParseDocument(sMessageToParse);
(* Parse XML nodes - Option 1 *)
xmlMachines := fbXml.ChildByName(xmlDoc, 'Machines');
xmlMachine1 := fbXml.ChildByAttribute(xmlMachines, 'Type', '1');
xmlMachine2 := fbXml.ChildByAttributeAndName(xmlMachines, 'Type', '2', 'Machine');
(* Parse XML nodes - Option 2 *)
xmlMachines := fbXml.ChildByName(xmlDoc, 'Machines');
xmlMachineNode := fbXml.Children(xmlMachines, xmlIterator);
WHILE NOT fbXml.IsEnd(xmlIterator) DO
xmlMachineNode := fbXml.Node(xmlIterator);
xmlMachineNodeValue := fbXml.NodeText(xmlMachineNode);
xmlMachineNode := fbXml.Children(xmlMachines, xmlIterator);
END_WHILE
(* Parse XML nodes - Option 3 *)
xmlMachines := fbXml.ChildByName(xmlDoc, 'Machines');
xmlIterator := fbXml.Begin(xmlMachines);
WHILE NOT fbXml.IsEnd(xmlIterator) DO
xmlMachineNode := fbXml.Node(xmlIterator);
xmlMachineNodeValue := fbXml.NodeText(xmlMachineNode);
xmlIterator := fbXml.Next(xmlIterator);
END_WHILE
(* Parse XML attributes - Option 1*)
xmlMachine1Attribute := fbXml.Attribute(xmlMachine1, 'Type');
xmlMachine2Attribute := fbXml.Attribute(xmlMachine2, 'Type');
(* Parse XML attributes - Option 2*)
xmlIterator := fbXml.AttributeBegin(xmlMachine1);
WHILE NOT fbXml.IsEnd(xmlIterator) DO
xmlMachineAttributeRef := fbXml.AttributeFromIterator(xmlIterator);
nMachineAttribute := fbXml.AttributeAsInt(xmlMachineAttributeRef);
xmlIterator := fbXml.Next(xmlIterator);
END_WHILE
(* Retrieve node values *)
sMachine1Name := fbXml.NodeText(xmlMachine1);
sMachine2Name := fbXml.NodeText(xmlMachine2);
(* Retrieve attribute values *)
nMachine1Attribute := fbXml.AttributeAsInt(xmlMachine1Attribute);
nMachine2Attribute := fbXml.AttributeAsInt(xmlMachine2Attribute);