FB_TcMessage

FB_TcMessage 1:

This function block represents a message from the TwinCAT 3 EventLogger.

Syntax

Definition:

FUNCTION_BLOCK FB_TcMessage EXTENDS FB_TcEventBase IMPLEMENTS I_TcMessage

Inheritance hierarchy

FB_TcEventBase

     FB_TcMessage

FB_TcMessage 2: Interfaces

Type

Description

I_TcMessage

Provides methods and properties for the message handling.

FB_TcMessage 3: Methods

Name

Definition location

Description

EqualsTo

Inherited from FB_TcEventBase

Compares the event with another instance.

EqualsToEventClass

Inherited from FB_TcEventBase

Compares the event class of the event with another event class.

EqualsToEventEntry

Inherited from FB_TcEventBase

Compares the event definition of the event with another event definition.

EqualsToEventEntryEx

Inherited from FB_TcEventBase

Compares the event definition of the event with another event definition.

GetJsonAttribute

Inherited from FB_TcEventBase

Returns the Json attribute.

Release

Inherited from FB_TcEventBase

Releases the instance created by the EventLogger again.

RequestEventClassName

Inherited from FB_TcEventBase

Requests the name of the event class.

RequestEventText

Inherited from FB_TcEventBase

Returns the text for the event.

Create

Local

Creates a message instance in the EventLogger.

CreateEx

Local

Creates a message instance in the EventLogger from an event definition.

SetJsonAttribute

Local

Sets the Json attribute.

Send

I_TcMessage

Sends a message.

FB_TcMessage 4: Properties

Name

Type

Access

Definition location

Description

eSeverity

TcEventSeverity

Get

Inherited from FB_TcEventBase

Returns the severity.

EventClass

GUID

Get

Inherited from FB_TcEventBase

Returns the GUID of the event class.

ipArguments

I_TcArguments

Get

Inherited from FB_TcEventBase

Returns the interface pointer for the arguments.

ipSourceInfo

I_TcSourceInfo

Get

Inherited from FB_TcEventBase

The SourceInfo is created internally as the default behavior. It then contains the symbol name of the function block that instances FB_TcMessage as SourceName and the object ID of the PLC instance as SourceID.

If the instance of FB_TcMessage is hidden with the attribute "hide", no symbol name can be created internally for the default behavior.

nEventId

nEventId

Get

Inherited from FB_TcEventBase

Returns the ID of the event.

stEventEntry

TcEventEntry

Get

Inherited from FB_TcEventBase

Returns the event definition.

nTimeSent

ULINT

Get

Local

Returns the time of the Send.

Requirements

Development environment

Target platform

PLC libraries to include

TwinCAT v3.1.4022.20

PC or CX (x64, x86, Arm®)

Tc3_EventLogger