Example: Memory ring FiFo (FB_MemRingBufferEx)
Here you can unpack the complete sources: MemRingBufferExExample.zip
A rising edge at bAdd causes new data elements (pubObj array) to be stored in the ring buffer. Via a rising edge at bGet the oldest data element can then be copied to the getObj variable.
Data elements that are not required are removed from the buffer via a rising edge at bRelease.
PROGRAM MAIN
VAR
    bReset  : BOOL := TRUE;
    bAdd, bGet, bRelease, bGetFree : BOOL;
    putObj  : ARRAY[0..3] OF BYTE :=[ 16#00, 16#AA, 16#BB, 16#CC];
    getObj  : ARRAY[0..3] OF BYTE :=[ 4(0)];
    bOk     : BOOL;
    nCount  : UDINT;
    cbSize  : UDINT;
    cbFree  : UDINT;
    fbBuffer: FB_MemRingBufferEx;
    buffer  : ARRAY[0..30] OF BYTE;
END_VARIF bReset THEN
    bReset := FALSE;
    fbBuffer.A_Reset( pBuffer := ADR( buffer ), cbBuffer := SIZEOF( buffer ),
                    bOk=>bOk,nCount=>nCount, cbSize=>cbSize, cbFree=>cbFree );
END_IF
IF bAdd THEN
    bAdd := FALSE;
    putObj[0] := putObj[0] + 1;(* modify data *)
    
    fbBuffer.A_AddTail( pBuffer := ADR( buffer ), cbBuffer := SIZEOF( buffer ),
                        pWrite := ADR( putObj ), cbWrite := SIZEOF( putObj ),
                        bOk=>bOk, nCount=>nCount, cbSize=>cbSize, cbFree=>cbFree );
    IF fbBuffer.bOk THEN
        ;(* Success *)
    ELSE
        ;(* Buffer overflow *)
    END_IF
END_IF
IF bGet THEN
    bGet := FALSE;
    fbBuffer.A_GetHead( pBuffer := ADR( buffer ), cbBuffer := SIZEOF( buffer ),
                        bOk=>bOk, nCount=>nCount, cbSize=>cbSize, cbFree=>cbFree );
    IF fbBuffer.bOk THEN
        (* Success *)
        MEMCPY( ADR( getObj ), fbBuffer.pRead, MIN( SIZEOF( getObj ), fbBuffer.cbRead ) );
    ELSE
        ;(* Buffer empty *)
    END_IF
END_IF
IF bRelease THEN
    bRelease := FALSE;
    fbBuffer.A_FreeHead( pBuffer := ADR( buffer ), cbBuffer := SIZEOF( buffer ),
                        bOk=>bOk, nCount=>nCount, cbSize=>cbSize, cbFree=>cbFree );
    IF fbBuffer.bOk THEN
        ;(* Success *)
    ELSE
        ;(* Buffer empty *)
    END_IF
END_IF
IF bGetFree THEN
    bGetFree := FALSE;
    fbBuffer.A_GetFreeSize( pBuffer := ADR( buffer ), cbBuffer := SIZEOF( buffer ),
                            bOk=>bOk, nCount=>nCount, cbSize=>cbSize, cbFree=>cbFree );
END_IFRequirements
Development environment  | Target platform  | PLC libraries to be integrated (category group)  | 
|---|---|---|
TwinCAT v3.1.0  | PC or CX (x86, x64, Arm®)  | Tc2_Utilities (System)  |