Example: File search (FB_EnumFindFileEntry, FB_EnumFindFileList)
Here you can unpack the complete sources: EnumFindFile.zip
Example: FB_EnumFindFileEntry (ST)
In the local TwinCAT system all files should be listed in the following directory: C:\Windows\system32\. The file names should be written as messages into the TwinCAT XAE error list. It should be possible to cancel this process. A rising edge at the bEnum variable starts the listing of found files. A rising edge at the bAbort variables aborts the process.
PROGRAM P_TestEnumEntry
VAR
    fbEnum: FB_EnumFindFileEntry := ( sNetID := '', tTimeout := T#5s, sPathName := 'C:\Windows\System32\*.*' );
    bEnum : BOOL;
    bAbort: BOOL;
    nState: BYTE;
END_VARCASE nState OF
    0:
        IF bEnum THEN             (* flag set ? *)
            bEnum       := FALSE;         (* reset flag *)
            fbEnum.eCmd := eEnumCmd_First;    (* enum first entry *)
            nState      := 1;
        END_IF
    1:    (* enum one entry *)
        IF bAbort THEN
            bAbort      := FALSE;
            fbEnum.eCmd := eEnumCmd_Abort;
        END_IF
        fbEnum( bExecute := FALSE );
        fbEnum( bExecute := TRUE );
        nState     := 2;
    2:    (* wait until function block not busy *)
        fbEnum( bExecute := FALSE );
        IF NOT fbEnum.bBusy THEN
            IF NOT fbEnum.bError THEN
                IF NOT fbEnum.bEOE THEN
                    ADSLOGSTR( ADSLOG_MSGTYPE_HINT OR ADSLOG_MSGTYPE_LOG, 'FB_EnumFindFileEntry, find file name: %s', fbEnum.stFindFile.sFileName );
                    fbEnum.eCmd := eEnumCmd_Next; (* enum next entry *)
                    nState      := 1;
                ELSE (* no more entries *)
                    nState      := 0;
                END_IF
            ELSE (* log error *)
                ADSLOGSTR( ADSLOG_MSGTYPE_ERROR OR ADSLOG_MSGTYPE_LOG, 'FB_EnumFindFileEntry error:%s', DWORD_TO_HEXSTR( fbEnum.nErrID, 0, FALSE ) );
                nState     := 0;
            END_IF
        END_IF
END_CASEThe log messages written into the TwinCAT XAE error list:
 
Example: FB_EnuFindFileList (FBD)
A rising edge at the bFirst variables activates the process. If successful the file names are entered in the fileList array variable.
PROGRAM P_TestEnumList
VAR
    fbEnum      : FB_EnumFindFileList;
    filesList   : ARRAY[1..10] OF ST_FindFileEntry;
    bFirst      : BOOL;
    bNext       : BOOL;
    bAbort      : BOOL;
    bBusy       : BOOL;
    bError      : BOOL;
    nErrID      : UDINT;
    bEOE        : BOOL;
    nFindFiles  : UDINT;
END_VAROnline view:
 
Requirements
Development environment  | Target platform  | PLC libraries to be integrated (category group)  | 
|---|---|---|
TwinCAT v3.1.0  | PC or CX (x86, x64, Arm®)  | Tc2_Utilities (System)  |