FB_GetOemOfLicenseId

The function block FB_GetOemLicenseId returns the OEM ID of a given license ID.
 Inputs
VAR_INPUT
    bExecute     : BOOL;
    tTimeout     : TIME := DEFAULT_ADS_TIMEOUT;
    sNetId       : T_AmsNetId;
    stLicenseId  : GUID;
END_VARName  | Type  | Description  | 
|---|---|---|
bExecute  | BOOL  | The function block is enabled by a positive edge at this input.  | 
tTimeout  | TIME  | States the length of the timeout that may not be exceeded by execution of the ADS command.  | 
sNetId  | T_AmsNetID  | AmsNetId (AMS network identifier) of the TwinCAT computer whose license status is to be read. For the local computer an empty string may be specified.  | 
stLicenseId  | License ID  | 
 Outputs
VAR_OUTPUT
    bBusy          : BOOL;
    bError         : BOOL;
    nErrId         : UDINT
    stOemId        : GUID;
END_VARName  | Type  | Description  | 
|---|---|---|
bBusy  | BOOL  | When the function block is enabled, this output is set and remains set until a feedback is received.  | 
bError  | BOOL  | If an error occurs during the transmission of the command, this output is set after the bBusy output is reset.  | 
nErrId  | UDINT  | Returns the ADS error number when the bError output is set.  | 
stOemId  | OEM ID  | 
Requirements
Development environment  | Target platform  | PLC libraries to be integrated (category group)  | 
|---|---|---|
TwinCAT v3.1.4024  | PC or CX (x86, x64, Arm®)  | Tc2_Utilities (System) >= 3.3.48.0  |