FILETIME64_TO_DT

The function "FILETIME64_TO_DT" converts the time in FILETIME format to DATE_AND_TIME format (DT). The DT format has a smaller value range than the FILETIME format and only offers second accuracy. For this reason, the FILETIME value to be converted is limited. The permitted minimum corresponds to value DT#1970-01-01-00:00:00 and the maximum to value DT#2106-02-06-06:28:15. Milliseconds are not considered in the conversion and are rounded down to the DATE_AND_TIME return value accordingly.
FUNCTION FILETIME64_TO_DT : DT
Inputs
VAR_INPUT
fileTime : T_FILETIME64;
END_VARName | Type | Description |
|---|---|---|
fileTime | The time to be converted in FILETIME format |
Example:
PROGRAM MAIN
VAR
timeAsFileTime : T_FILETIME64;
timeAsDT : DT;
END_VARtimeAsFileTime := F_GetSystemTime();
timeAsDT := FILETIME64_TO_DT( timeAsFileTime );Requirements
Development environment | Target platform | PLC libraries to be integrated (category group) |
|---|---|---|
TwinCAT v3.1.4024 | PC or CX (x86, x64, Arm®) | Tc2_Utilities (System) >= 3.3.44.0 |