E_S_UPS_State
Data type | Description |
|---|---|
eSUPS_PowerOK | In all modes: supply voltage is OK. |
eSUPS_PowerFailure | In all modes: supply voltage faulty (applied for one cycle only) |
eSUPS_WritePersistentData | In eSUPS_WrPersistData_Shutdown mode: writing is active for persistent data. In eSUPS_WrPersistData_NoShutdown mode: writing is active for persistent data. |
eSUPS_QuickShutdown | In eSUPS_WrPersistData_Shutdown mode: quick shutdown is active. In eSUPS_ImmediateShutdown: quick shutdown is active. |
eSUPS_WaitForRecover | In eSUPS_WrPersistData_NoShutdown mode: wait for voltage recovery. In eSUPS_CheckPowerStatus mode: wait for voltage recovery. |
eSUPS_WaitForPowerOFF | In eSUPS_WrPersistData_Shutdown mode: wait for the UPS to perform shut down. In eSUPS_ImmediateShutdown mode: wait for the UPS to perform shutdown. |